相关论文: A Model-Based Scatter Artifacts Correction for Con…

200 篇论文

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

Computer-Assisted Interventions enable clinicians to perform precise, minimally invasive procedures, often relying on advanced imaging methods. Cone-beam computed tomography (CBCT) can be used to facilitate computer-assisted interventions,…

图像与视频处理 · 电气工程与系统科学 2024-12-04 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

Cone beam computed tomography (CBCT) is an emerging medical imaging technique to visualize the internal anatomical structures of patients. During a CBCT scan, several projection images of different angles or views are collectively utilized…

图像与视频处理 · 电气工程与系统科学 2024-01-18 Heejun Shin , Taehee Kim , Jongho Lee , Se Young Chun , Seungryung Cho , Dongmyung Shin

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray…

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

图像与视频处理 · 电气工程与系统科学 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Cone-beam computed tomography (CBCT) has become a vital imaging technique in various medical fields but scatter artifacts are a major limitation in CBCT scanning. This challenge is exacerbated by the use of large flat panel 2D detectors.…

信号处理 · 电气工程与系统科学 2024-05-24 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw…

图像与视频处理 · 电气工程与系统科学 2024-10-01 Ziheng Deng , Hua Chen , Yongzheng Zhou , Haibo Hu , Zhiyong Xu , Jiayuan Sun , Tianling Lyu , Yan Xi , Yang Chen , Jun Zhao

Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight…

医学物理 · 物理学 2021-02-01 Ignacio O. Romero , Changqing Li

X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…

医学物理 · 物理学 2025-05-27 Yang Zou , Meili Qi , Jianhua Zhang , Difei Zhang , Shuwei Wang , Jiale Zhang , Shengkun Yao , Huaidong Jiang

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

医学物理 · 物理学 2022-05-24 Junbo Peng

Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To…

医学物理 · 物理学 2023-08-21 Farhang Bayat , Dan Ruan , Moyed Miften , Cem Altunbas

Computed Tomography (CT) using synchrotron radiation is a powerful technique that, compared to lab-CT techniques, boosts high spatial and temporal resolution while also providing access to a range of contrast-formation mechanisms. The…

图像与视频处理 · 电气工程与系统科学 2025-01-20 Jiayang Shi , Daniel M. Pelt , K. Joost Batenburg

In dental cone-beam computed tomography (CBCT), compact and cost-effective system designs often use small detectors, resulting in a truncated field of view (FOV) that does not fully encompass the patient's head. In iterative reconstruction…

计算机视觉与模式识别 · 计算机科学 2025-08-12 Hyoung Suk Park , Kiwan Jeon

Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…

量子物理 · 物理学 2023-09-12 Kyungtaek Jun

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

图像与视频处理 · 电气工程与系统科学 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

Background: Dual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue visualization. However, the performance of DE CBCT is…

医学物理 · 物理学 2023-06-26 Cem Altunbas

The purpose of this study is to develop a deep learning based method that can automatically generate segmentations on cone-beam CT (CBCT) for head and neck online adaptive radiation therapy (ART), where expert-drawn contours in planning CT…

医学物理 · 物理学 2021-02-02 Xiao Liang , Howard Morgan , Dan Nguyen , Steve Jiang

Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally…

计算机视觉与模式识别 · 计算机科学 2026-02-10 Johannes Thalhammer , Tina Dorosti , Sebastian Peterhansl , Daniela Pfeiffer , Franz Pfeiffer , Florian Schaff

In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…