中文
相关论文

相关论文: CALICE Digital Hadron Calorimeter: Calibration and…

200 篇论文

Particle Flow Algorithms (PFAs) have been proposed as a method of improving the jet energy resolution of future colliding beam detectors. PFAs require calorimeters with high granularity to enable three-dimensional imaging of events. The…

仪器与探测器 · 物理学 2019-08-13 Kurt Francis

The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of…

仪器与探测器 · 物理学 2015-06-19 Jose Repond

The DHCAL collaboration is assembling a large scale prototype Digital Hadron Calorimeter (DHCAL). The calorimeter utilizes Resistive Plate Chambers (RPCs) as active medium and features of the order of 400,000 1 \times 1 cm2 pads with binary…

仪器与探测器 · 物理学 2010-05-05 Jose Repond

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE…

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

The Digital Hadron Calorimeter (DHCAL) 1m3 physics prototype was constructed and has been tested in particle beams. We report the preliminary results from the analysis of both positon and pion events of momenta between 2 and 60 GeV/c. These…

仪器与探测器 · 物理学 2019-08-13 Lei Xia

The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two…

仪器与探测器 · 物理学 2016-07-13 Z. Deng , Y. Li , Y. Wang , Q. Yue , Z. Yang , J. Apostolakis , G. Folger , C. Grefe , V. Ivantchenko , A. Ribon , V. Uzhinskiy , D. Boumediene , C. Carloganu , V. Français , G. Cho , D-W. Kim , S. C. Lee , W. Park , S. Vallecorsa , S. Cauwenbergh , M. Tytgat , A. Pingault , N. Zaganidis , E. Brianne , A. Ebrahimi , K. Gadow , P. Göttlicher , C. Günter , O. Hartbrich , B. Hermberg , A. Irles , F. Krivan , K. Krüger , J. Kvasnicka , S. Lu , B. Lutz , V. Morgunov , C. Neubüser , A. Provenza , M. Reinecke , F. Sefkow , S. Schuwalow , H. L. Tran , E. Garutti , S. Laurien , M. Matysek , M. Ramilli , S. Schroeder , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , K. Kawagoe , H. Hirai , Y. Sudo , T. Suehara , H. Sumida , T. Yoshioka , E. Cortina Gil , S. Mannai , V. Buridon , C. Combaret , L. Caponetto , R. Eté , G. Garillot , G. Grenier , R. Han , J. C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , J. Berenguer Antequera , E. Calvo Alamillo , M. -C. Fouz , J. Marin , J. Puerta-Pelayo , A. Verdugo , M. Chadeeva , M. Danilov , M. Gabriel , P. Goecke , C. Kiesling , N. vanderKolk , F. Simon , M. Szalay , S. Bilokin , J. Bonis , P. Cornebise , F. Richard , R. Pöschl , J. Rouëné , A. Thiebault , D. Zerwas , M. Anduze , V. Balagura , K. Belkadhi , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , Y. Haddad , F. Magniette , M. Ruan , M. Rubio-Roy , K. Shpak , H. Videau , D. Yu , S. Callier , S. Conforti di Lorenzo , F. Dulucq , G. Martin-Chassard , Ch. de la Taille , L. Raux , N. Seguin-Moreau , K. Kotera , H. Ono , T. Takeshita , F. Corriveau

The Digital Hadron Calorimeter (DHCAL) is a large prototype of an imaging calorimeter using Resistive Plate Chambers (RPCs) as active media. The readout is segmented into 1\times1 cm2 pads, each with a single bit resolution, hence the…

仪器与探测器 · 物理学 2012-04-17 Jose Repond

The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active…

仪器与探测器 · 物理学 2016-05-04 V. Buridon , C. Combaret , L. Caponetto , R. Eté , G. Garillot , G. Grenier , R. Han , J. C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , J. Berenguer Antequera , E. Calvo Alamillo , M. -C. Fouz , J. Marin , J. Puerta-Pelayo , A. Verdugo , E. Cortina Gil , S. Mannai , S. Cauwenbergh , M. Tytgat , A. Pingault , N. Zaganidis , M. Anduze , V. Balagura , K. Belkadhi , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , Y. Haddad , M. Ruan , K. Shpak , H. Videau , D. Yu , S. Callier , S. Conforti di Lorenzo , F. Dulucq , G. Martin-Chassard , Ch. de la Taille , L. Raux , N. Seguin-Moreau , D. Boumediene , C. Carloganu , V. Français , J. Bonis , B. Bouquet , P. Cornebise , Ph. Doublet , M. Faucci-Giannelli , T. Frisson , G. Guilhem , H. Li , F. Richard , R. Pöschl , J. Rouëné , F. Wicek , Z. Zhang , Z. Deng , Y. Li , Y. Wang , Q. Yue , Z. Yang , G. Cho , D-W. Kim , S. C. Lee , W. Park , S. Vallecorsa , E. Brianne , A. Ebrahimi , K. Gadow , P. Göttlicher , C. Günter , O. Hartbrich , B. Hermberg , A. Irles , F. Krivan , K. Krüger , J. Kvasnicka , S. Lu , B. Lutz , V. Morgunov , C. Neubüser A. Provenza , M. Reinecke , F. Sefkow , S. Schuwalow , H. L. Tran , E. Garutti , S. Laurien , M. Matysek , M. Ramilli , S. Schroeder , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , N. Kirikova , V. Kozlov , P. Smirnov , Y. Soloviev , M. Chadeeva , M. Danilov , M. Gabriel , P. Goecke , C. Kiesling , N. van der Kolk , F. Simon , C. Soldner , M. Szalay , L. Weuste , D. Jeans , S. Komamiya , H. Nakanishi , D. Benchekroun , A. Hoummada , Y. Khoulaki

An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and…

仪器与探测器 · 物理学 2016-12-13 C. Adloff , Y. Karyotakis , J. Repond , A. Brandt , H. Brown , K. De , C. Medina , J. Smith , J. Li , M. Sosebee , A. White , J. Yu , T. Buanes , G. Eigen , Y. Mikami , O. Miller , N. K. Watson , J. A. Wilson , T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , M. Oreglia , M. Benyamna , C. Cârloganu , P. Gay , J. Ha , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , G. Lima , V. Zutshi , V. A. Babkin , S. N. Bazylev , Yu. I. Fedotov , V. M. Slepnev , I. A. Tiapkin , S. V. Volgin , J. -Y. Hostachy , L. Morin , N. D?Ascenzo , U. Cornett , D. David , R. Fabbri , G. Falley , N. Feege , K. Gadow , E. Garutti , P. Göttlicher , T. Jung , S. Karstensen , V. Korbel , A. -I. Lucaci-Timoce , B. Lutz , N. Meyer , V. Morgunov , M. Reinecke , S. Schätzel , S. Schmidt , F. Sefkow , P. Smirnov , A. Vargas-Trevino , N. Wattimena , O. Wendt , M. Groll , R. -D. Heuer , S. Richter , J. Samson , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , E. J. Kim , G. Kim , D-W. Kim , K. Lee , S. C. Lee , K. Kawagoe , Y. Tamura , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , M. Faucci Giannelli , M. G. Green , F. Salvatore , R. Kieffer , I. Laktineh , M. C Fouz , D. S. Bailey , R. J. Barlow , R. J. Thompson , M. Batouritski , O. Dvornikov , Yu. Shulhevich , N. Shumeiko , A. Solin , P. Starovoitov , V. Tchekhovski , A. Terletski , B. Bobchenko , M. Chadeeva , M. Danilov , O. Markin , R. Mizuk , V. Morgunov , E. Novikov , V. Rusinov , E. Tarkovsky , V. Andreev , N. Kirikova , A. Komar , V. Kozlov , P. Smirnov , Y. Soloviev , A. Terkulov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , N. Baranova , E. Boos , L. Gladilin , D. Karmanov , M. Korolev , M. Merkin , A. Savin , A. Voronin , A. Topkar , A. Freyk , C. Kiesling , S. Lu , K. Prothmann , K. Seidel , F. Simon , C. Soldner , L. Weuste , B. Bouquet , S. Callier , P. Cornebise , F. Dulucq , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , M. Ruan , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , G. Gaycken , R. Cornat , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rougé , J-Ch. Vanel , H. Videau , K-H. Park , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , Yu. Arestov , V. Ammosov , B. Chuiko , V. Gapienko , Y. Gilitski , V. Koreshev , A. Semak , Yu. Sviridov , V. Zaets , B. Belhorma , M. Belmir , A. Baird , R. N. Halsall , S. W. Nam , I. H. Park , J. Yang , Jong-Seo Chai , Jong-Tae Kim , Geun-Bum Kim , Y. Kim , J. Kang , Y. -J. Kwon , Ilgoo Kim , Taeyun Lee , Jaehong Park , Jinho Sung , S. Itoh , K. Kotera , M. Nishiyama , T. Takeshita , S. Weber , C. Zeitnitz

This talk reports on recent progress concerning the development of a Digital Hadron Calorimeter with Resistive Plate Chambers as active elements. After the successful testing of a Digital Hadron Calorimeter prototype, the DHCAL, in the…

仪器与探测器 · 物理学 2013-12-16 J. Repond

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded…

The CALICE collaboration investigates diferent technology options for highly granular calorimeters for detectors at a future electron-positron collider. One of the devices constructed and tested by this collaboration is a 1m3 prototype of a…

仪器与探测器 · 物理学 2019-08-15 Jaroslav Zalesak

The Analogue Hadron Calorimeter (AHCAL) is being developed within the CALICE collaboration for experiments at a future lepton collider. It is a sampling calorimeter with alternating layers of steel absorber plates and plastic scintillator…

仪器与探测器 · 物理学 2020-04-02 Olin Pinto

The CALICE Semi-digital hadronic calorimeter built in 2011, was installed and tested during two periods of two weeks each in 2012 at CERN SPS facilities. The detector has more than 450000 channels with a semi-digital readout distributed on…

仪器与探测器 · 物理学 2019-08-16 Y. Haddad

The Analog Hadron Calorimeter (AHCAL) concept developed by the CALICE collaboration is a highly granular sampling calorimeter with \SI{3x3}{\square\centi\meter} plastic scintillator tiles individually read out by silicon photomultipliers…

仪器与探测器 · 物理学 2021-05-19 Lorenz Emberger

The SDHCAL technological prototype is a $1 \times 1 \times 1.3$ m$^3$ high-granularity Semi-Digital Hadronic CALorimeter using Glass Resistive Plate Chambers as sensitive medium. It is one of the two HCAL options considered by the ILD…

仪器与探测器 · 物理学 2015-06-22 Gérald Grenier

Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now…

仪器与探测器 · 物理学 2019-04-26 Christian Graf

The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out…

仪器与探测器 · 物理学 2019-05-22 Felix Sefkow , Frank Simon
‹ 上一页 1 2 3 10 下一页 ›