中文
相关论文

相关论文: Dynamic Bowtie for Fan-beam CT

200 篇论文

Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…

医学物理 · 物理学 2021-09-22 Emily Cloutier , Louis Archambault , Luc Beaulieu

Accurate dose calculations in proton therapy rely on high-quality CT images. While planning CTs (pCTs) serve as a reference for dosimetric planning, Cone Beam CT (CBCT) is used throughout Adaptive Radiotherapy (ART) to generate sCTs for…

计算机视觉与模式识别 · 计算机科学 2025-03-12 David Vallmanya Poch , Yorick Estievenart , Elnura Zhalieva , Sukanya Patra , Mohammad Yaqub , Souhaib Ben Taieb

Spectral CT has shown promise for high-sensitivity quantitative imaging and material decomposition. This work presents a new device called a spatial-spectral filter (SSF) which consists of a tiled array of filter materials positioned near…

医学物理 · 物理学 2020-10-16 Matthew Tivnan , Wenying Wang , Grace Gang , J. Webster Stayman

Generating synthetic CT (sCT) from MRI or CBCT plays a crucial role in enabling MRI-only and CBCT-based adaptive radiotherapy, improving treatment precision while reducing patient radiation exposure. To address this task, we adopt a fully…

计算机视觉与模式识别 · 计算机科学 2026-04-24 Arnela Hadzic , Simon Johannes Joham , Martin Urschler

Differential dynamic microscopy (DDM) is a form of video image analysis that combines the sensitivity of scattering and the direct visualization benefits of microscopy. DDM is broadly useful in determining dynamical properties including the…

软凝聚态物质 · 物理学 2022-04-12 Mengyang Gu , Yimin Luo , Yue He , Matthew E. Helgeson , Megan T. Valentine

Prostate cancer is a major global health concern, requiring advancements in robotic surgery and diagnostics to improve patient outcomes. A phantom is a specially designed object that simulates human tissues or organs. It can be used for…

医学物理 · 物理学 2025-08-25 Sizhe Tian , Yinoussa Adagolodjo , Jeremie Dequidt

In this paper, a novel and robust algorithm is proposed for adaptive beamforming based on the idea of reconstructing the autocorrelation sequence (ACS) of a random process from a set of measured data. This is obtained from the first column…

信息论 · 计算机科学 2021-06-25 Saeed Mohammadzadeh , Vitor H. Nascimento , Rodrigo C. de Lamare , Osman Kukrer

This study proposes a novel imaging and reconstruction framework for dual-energy cone-beam CT (DECBCT) using only two orthogonal X-ray projections at different energy levels (2V-DECBCT). The goal is to enable fast and low-dose DE volumetric…

医学物理 · 物理学 2025-04-18 Junbo Peng , Tonghe Wang , Shaoyan Pan , Xiaofeng Yang

One of the major challenges in the science of maxillofacial radiology imaging is the various artifacts created in images taken by cone beam computed tomography (CBCT) imaging systems. Among these artifacts, motion artifact, which is created…

医学物理 · 物理学 2024-10-02 R. Baghbani , M. Ashoorirad , F. Salemi , Med Amine Laribi , M. Mostafapoor

Spectral CT is an emerging modality that uses a data acquisition scheme with varied spectral responses to provide enhanced material discrimination in addition to the structural information of conventional CT. Existing clinical and…

In this work, we design, fabricate and characterize a compact, broadband and highly sensitive integrated photonic electromagnetic field sensor based on a silicon-organic hybrid modulator driven by a bowtie antenna. The large electro-optic…

Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…

医学物理 · 物理学 2025-02-04 S. Gros , J. Bian , J. Jackson , M. Delafuente , H. Kang , W. Small , M. Mahesh

Objective: This study aims to develop and validate a novel framework, iPhantom, for automated creation of patient-specific phantoms or digital-twins (DT) using patient medical images. The framework is applied to assess radiation dose to…

Imaging of teeth is very important to doctors in the diagnosis and treatment of dental diseases. The main imaging modality currently used is Cone-Beam Computed Tomography (CBCT), which however suffers from ionizing radiation causing…

医学物理 · 物理学 2023-04-13 Yuting Shen , Yiyun Wang , Chengxiao Liu , Niansong Ye , Feng Gao , Lunguo Xia , Bing Fang , Fei Gao

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

医学物理 · 物理学 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang

Coherent X-ray scattering techniques are critical for investigating the fundamental structural properties of materials at the nanoscale. While advancements have made these experiments more accessible, real-time analysis remains a…

机器学习 · 计算机科学 2025-07-21 Aileen Luo , Tao Zhou , Ming Du , Martin V. Holt , Andrej Singer , Mathew J. Cherukara

Cone Beam CT (CBCT) plays a crucial role in Adaptive Radiation Therapy (ART) by accurately providing radiation treatment when organ anatomy changes occur. However, CBCT images suffer from scatter noise and artifacts, making relying solely…

图像与视频处理 · 电气工程与系统科学 2023-08-08 Linjie Fu , Xia Li , Xiuding Cai , Dong Miao , Yu Yao , Yali Shen

Laser frequency combs (LFCs) are an important component of Doppler radial velocity (RV) spectroscopy that pushes fractional precision to the $10^{-10}$ level, as required to identify and characterize Earth-like exoplanets. However, large…

天体物理仪器与方法 · 物理学 2025-02-11 Pooja Sekhar , Connor Fredrick , Peter Zhong , Abijith S Kowligy , Arman Cingöz , Scott A Diddams

Pulsatile changes in retinal vascular geometry over the cardiac cycle have clinical implications for the diagnosis of ocular and systemic vascular diseases, including ischemia, coronary heart diseases, and diabetes mellitus and its…

图像与视频处理 · 电气工程与系统科学 2020-09-24 Pranjal Rai , Sachin Jangir , Tanvir Singh Bal

We demonstrate in vivo endoscopic optical coherence tomography (OCT) imaging in the forward direction using a flexible fiber bundle. In comparison to current conventional forward looking probe schemes, our approach simplifies the endoscope…