中文
相关论文

相关论文: Thermal architecture for the SPIDER flight cryosta…

200 篇论文

We describe a helium source cell for use in cryogenic experiments that is hermetically sealed $in$ $situ$ on the cold plate of a cryostat. The source cell is filled with helium gas at room temperature and subsequently sealed using a cold…

仪器与探测器 · 物理学 2023-11-06 K. E. Castoria , H. Byeon , J. Theis , N. R. Beysengulov , E. O. Glen , G. Koolstra , M. Sammon , S. A. Lyon , J. Pollanen , D. G. Rees

A compact cryogenic calibration target is presented that has a peak diffuse reflectance, $R \le 0.003$, from $800-4,800\,{\rm cm}^{-1}$ $(12-2\,\mu$m). Upon expanding the spectral range under consideration to $400-10,000\,{\rm cm}^{-1}$…

仪器与探测器 · 物理学 2014-04-22 Edward J. Wollack , Robin E. Kinzer , Stephan A. Rinehart

The Next Generation Balloon-borne Large Aperture Submillimeter Telescope (BLAST-TNG) is a submillimeter polarimeter designed to map interstellar dust and galactic foregrounds at 250, 350, and 500 microns during a 24-day Antarctic flight.…

The understanding of complex and/or large vacuum systems operating at cryogenic temperatures requires a specific knowledge of the vacuum science at such temperatures. At room temperature, molecules with a low binding energy to a surface are…

仪器与探测器 · 物理学 2020-06-03 Vincent Baglin

Using first-principles density functional theory simulations, we have observed that the scandium decorated C$_{24}$ fullerene can adsorb up to six hydrogen molecules with an average adsorption energy of -0.35 eV per H$_2$ and average…

材料科学 · 物理学 2021-11-05 Vikram Mahamiya , Alok Shukla , Brahmananda Chakraborty

Here we report the performance of a small scale 4 K pulse tube cryocooler operating with a low input power reaching a minimum temperature of 2.2 K, as well as a cooling capacity of over 240 mW at 4.2 K. The compressor is air cooled and can…

We present the design and performance of a cryogenic scanning tunneling microscope (STM) which operates inside a water-cooled Bitter magnet, which can attain a magnetic field of up to 38 T. Due to the high vibration environment generated by…

We describe a technique for measuring focus errors in a cryogenic, wide-field, near-infrared space telescope. The measurements are made with a collimator looking through a large vacuum window, with a reflective cold filter to reduce…

天体物理仪器与方法 · 物理学 2024-10-22 Samuel S. Condon , Stephen Padin , James Bock , Howard Hui , Phillip Korngut , Chi Nguyen , Jordan Otsby

Fundamental solid state physics phenomena typically occur at very low temperatures, requiring liquid helium cooling in experimental studies. Transmission electron microscopy is a well-established characterization method, which allows…

仪器与探测器 · 物理学 2019-10-02 Felix Börrnert , Felix Kern , Franziska Seifert , Thomas Riedel , Heiko Müller , Bernd Büchner , Axel Lubk

Among the global efforts to directly detect dark matter, the only positive claim so far relies on NaI(Tl) crystal detectors, making this technology of particular interest. ASTAROTH is a project aimed at developing the next generation of…

仪器与探测器 · 物理学 2026-02-09 F. Alessandria , F. B. Armani , S. Coelli , D. Cortis , D. D'Angelo , E. Martinenghi , M. Monti , D. Orlandi , M. Sorbi , V. Toso , A. Zani

SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma) is a full-scale prototype of the ITER NBI source. It is based on the concept of inductive coupling between radio-frequency current drive and plasma. Present…

等离子体物理 · 物理学 2024-09-10 D. López-Bruna , S. Denizeau , I. Predebon , A. La Rosa , C. Poggi , P. Agostinetti

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…

仪器与探测器 · 物理学 2025-08-28 D. P. Kapasi , T. G. McRae , J. Eichholz , P. A. Altin , D. E. McClelland , B. J. J. Slagmolen

Possible light bosonic dark matter interactions with the Standard Model photon have been searched by microwave resonant cavities. In this paper, we demonstrate the cryogenic readout system calibration of a 7.138 GHz copper cavity with a…

A model of a multilayer device with non-trivial geometrical structure and nonlinear dependencies of thermodynamic material properties at cryogenic temperatures is suggested. A considered device, called cryogenic cell, is intended for use in…

计算物理 · 物理学 2015-11-20 Alexander Ayriyan , Jan Busa , Eugeny E. Donets , Hovik Grigorian , Jan Pribis

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This…

The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of…

In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for…

仪器与探测器 · 物理学 2016-10-05 Tomas Kralik , Pavel Hanzelka , Vera Musilova , Ales Srnka

We present the thermal model of the Balloon-borne Large-Aperture Submillimeter Telescope for Polarimetry (BLASTPol). This instrument was successfully flown in two circumpolar flights from McMurdo, Antarctica in 2010 and 2012. During these…

The Subarcsecond Telescope And BaLloon Experiment, STABLE, is the fine stage of a guidance system for a high-altitude ballooning platform designed to demonstrate subarcsecond pointing stability, over one minute using relatively dim guide…