30厘米长CsI(Tl)晶体的抗辐射硬度
仪器与探测器
2016-08-29 v1 高能物理 - 实验
摘要
给出了暴露于1 MeV光子剂量2、10、35、100和1000 Gy下的30厘米长CsI(Tl)闪烁晶体性能退化的测量结果。研究了来自BABAR和Belle实验的一组备用晶体的光产额、光产额纵向非均匀性、闪烁衰减时间、能量分辨率和时间分辨率随这些剂量的变化。此外,提出了一个模型,该模型用辐照下吸收中心浓度的增加来描述光输出损失随剂量变化的平台现象。
引用
@article{arxiv.1608.07556,
title = {Radiation Hardness of 30 cm Long CsI(Tl) Crystals},
author = {Savino Longo and John Michael Roney},
journal= {arXiv preprint arXiv:1608.07556},
year = {2016}
}
备注
This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/1748-0221/11/08/P08017