相关论文: Radiation Hardness of 30 cm Long CsI(Tl) Crystals
This paper is devoted to the study of a degradation of CsI(Tl)crystals scintillation characteristics under irradiation with gamma-quanta at the uniformly distributed absorbed dose up to 3700 rad. The sample set consisted of 25 crystals of…
A photomultiplier setup for precise relative CsI(Tl) crystal light yield and uniformity measurements is described. It is used for wrapping material studies to optimize the uniformity and the yield of the light output of 36 cm long crystals.…
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded…
Scintillation characteristics of a thallium doped sodium iodide (NaI(Tl)) crystal with a dimension of 0.6 x 0.6 x 2 cm3 are studied by attaching a silicon photomultiplier (SiPM) direct to the crystal over a temperature range from 93 to 300…
A simple formalism describing the light response of CsI(Tl) to heavy ions, which quantifies the luminescence and the quenching in terms of the competition between radiative transitions following the carrier trapping at the Tl activator…
We have investigated scintillation light distribution in BaF$_{2}$ and pure CsI crystals with dimensions 3x3x20 cm$^{3}$ using the Geant4 toolkit. The diffuse wrapping material is selected as coating for the crystals. The simulated cosmic…
The scintillation light output of a pure and a Thallium doped Sodium Iodide (NaI) crystal under irradiation with 5.486MeV \alpha -particles has been measured over a temperature range from 1.7K to 300K. Estimates of the decay time constant…
This article describes the crystal selection and quality control utilized to develop and calibrate a high resolution array of CsI(TI) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the…
The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…
To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response…
Crystal scintillators provide potential merits for the pursuit of low-energy low-background experiments. A CsI(Tl) scintillating crystal detector is being constructed to study low-energy neutrino physics at a nuclear reactor, while projects…
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It…
A light yield of 20.4 $\pm$ 0.8 photoelectrons/keV was achieved with an undoped CsI crystal coupled directly to a photomultiplier tube at 77 Kelvin. This is by far the largest yield in the world achieved with CsI crystals. An energy…
The scintillation characteristics of 1 g undoped CsI crystal were studied by directly coupling two silicon photomultipliers(SiPMs) over a temperature range from room temperature to 86 K. The scintillation decay time and light output were…
The linear response of CsI(Tl) crystals to $\gamma$-rays plays a crucial role in their calibration, as any deviation from linearity can introduce systematic errors not negligible in the measurement of $\gamma$ energy spectra, particularly…
Nuclear and high energy physics research has a need for new, high performance scintillators with high light yields; high densities, fast decay times, and are radiation hard. In this paper we present crystal growth and results from 16-mm…
Eight PbWO4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 E13 p/cm2. The damage recovery in these crystals, stored in the dark at room…
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed.…
Scintillators play an important role in radiation detection and imaging. Thallium-doped cesium iodide (CsI:Tl) and sodium iodide (NaI:Tl) are two of the major scintillators that have been used for many applications for many decades. In this…
0.5%, 1%, 3% and 5% Ce-concentration single crystals of Tl2LiLuCl6 were grown from the melt using two zone vertical Bridgman technique. X-ray induced emission spectra showed Ce3+ emission between 370 nm and 540 nm wavelength range. Energy…