In a multiprocessor system on chip (MPSoC) IC the processor is one of the highest heat dissipating devices. The temperature generated in an IC may vary with floor plan of the chip. This paper proposes an integration and thermal analysis…

Emerging Technologies · Computer Science 2012-01-24 Ramya Menon C. , Vinod Pangracious

The interaction of an object with its surrounding bath can lead to a coupling between the object's internal degrees of freedom and its center-of-mass motion. This coupling is especially important for nanomechanical oscillators, which are…

Instrumentation and Detectors · Physics 2018-04-10 Erik Hebestreit , René Reimann , Martin Frimmer , Lukas Novotny

We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses…

Instrumentation and Detectors · Physics 2020-03-24 Andreas Reifenberger , Andreas Reiser , Sebastian Kempf , Andreas Fleischmann , Christian Enss

Nanodiamond hosting temperature-sensing centers constitutes a closed thermodynamic system, with the only window of energy exchange with the environment without direct contacts of a sensor with intracellular substrates, which is in fact the…

Controlling the temperature in architectures involving nanoparticles and substrates is a key issue for applications involving micro and nanoscale heat transfer. We study the thermal behavior of a single nanoparticle interacting with a flat…

Optics · Physics 2017-03-03 Houssem Kallel , Rémi Carminati , Karl Joulain

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic…

Instrumentation and Methods for Astrophysics · Physics 2022-04-27 S. Masi , E. S. Battistelli , P. de Bernardis , C. Chapron , F. Columbro , G. D'Alessandro , M. De Petris , L. Grandsire , J. -Ch. Hamilton , S. Marnieros , L. Mele , A. May , A. Mennella , C. O'Sullivan , A. Paiella , F. Piacentini , M. Piat , L. Piccirillo , G. Presta , A. Schillaci , A. Tartari , J. -P. Thermeau , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , G. Amico , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Bélier , A. Baù , D. Bennett , L. Bergé , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , R. Charlassier , A. C. Cobos Cerutti , A. Coppolecchia , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. García , M. E. García Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gómez Berisso , M. González , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versillé , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , L. Lamagna , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , M. McCulloch , D. Melo , L. Montier , L. Mousset , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , G. Pisano , M. Platino , G. Polenta , D. Prêle , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , C. G. Scóccola , S. Scully , S. Spinelli , G. Stankowiak , M. Stolpovskiy , A. D. Supanitsky , P. Timbie , M. Tomasi , G. Tucker , C. Tucker , D. Viganò , N. Vittorio , F. Wicek , M. Wright , A. Zullo

This paper presents the characterization of microwave passive components, including metal-oxide-metal (MoM) capacitors, transformers, and resonators, at deep cryogenic temperature (4.2 K). The variations in capacitance, inductance and…

Many quantum technologies, including quantum computers, quantum heat engines, and quantum sensors, rely on operating conditions in the subkelvin regime. It is therefore desirable to develop practical tools and methods for the precise…

Mesoscale and Nanoscale Physics · Physics 2025-03-28 Riya Baruah , Pedro Portugal , Joachim Wabnig , Christian Flindt

Energy dissipation is a fundamental process governing the dynamics of physical, chemical, and biological systems. It is also one of the main characteristics distinguishing quantum and classical phenomena. In condensed matter physics, in…

This paper outlines the establishment of a generic cryogenic CMOS database in which key electrical parameters and transfer characteristics of the MOSFETs are quantified as functions of device size, temperature/frequency responses.…

We have fabricated a custom cryogenic Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuit that has a higher measurement bandwidth compared with conventional room temperature electronics. This allowed implementing single shot…

Wide attention has been focused on cryogenic CMOS (Cryo-CMOS) operation because of its wide application and the improvement of CMOS performance. However, hot carrier degradation (HCD) becomes worsening at cryogenic temperature, which…

Applied Physics · Physics 2021-10-22 Yuanke Zhang , Chao Luo , Tengteng Lu , Yujing Zhang , Jun Xu , Guoping Guo

We make use of a custom-designed cryo-CMOS multiplexer (MUX) to enable multiple quantum devices to be characterized in a single cool-down of a dilution refrigerator. Combined with a packaging approach that integrates cryo-CMOS chips and a…

Applied Physics · Physics 2019-08-22 S. J. Pauka , K. Das , J. M. Hornibrook , G. C. Gardner , M. J. Manfra , M. C. Cassidy , D. J. Reilly

We report the cooling of electrons in nanoelectronic Coulomb blockade thermometers below 4 mK. Above 7 mK the devices are in good thermal contact with the environment, well isolated from electrical noise, and not susceptible to…

Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator…

The Coulomb Blockade Thermometer (CBT) is a primary thermometer for cryogenic temperatures, with demonstrated operation from below 1 mK up to 60 K. Its performance as a primary thermometer has been verified at temperatures from 20 mK to 200…

Probes that measure the local thermal properties of systems out of equilibrium are emerging as new tools in the study of nanoscale systems. One can then measure the temperature of a probe that is weakly coupled to a bias-driven system. By…

Strongly Correlated Electrons · Physics 2015-05-13 LvZhou Ye , Dong Hou , Xiao Zheng , YiJing Yan , Massimiliano Di Ventra

A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum…

We present a realisation of high bandwidth instrumentation at cryogenic temperatures and for dilution refrigerator operation that possesses advantages over methods using radio-frequency single electron transistor or transimpedance…

Silicon carbide is a wide-bandgap semiconductor with an emerging CMOS technology platform and it is widely deployed in high power and harsh environment electronics. This material is also attracting interest for quantum technologies through…

Applied Physics · Physics 2026-05-05 Megan Powell , Euan Parry , Conor McGeough , Alexander Zotov , Alessandro Rossi