中文
相关论文

相关论文: Do the precise measurements of the Casimir force a…

200 篇论文

We compare theoretical expectations for the Casimir force with the results of precise measurements. The force is calculated at finite temperature for multilayered covering of the bodies using the Lifshitz theory. We argue that the…

量子物理 · 物理学 2007-05-23 V. B. Svetovoy , M. V. Lokhanin

We report an improved precision measurement of the Casimir force. The force is measured between a large Al coated sphere and flat plate using an Atomic Force Microscope. The primary experimental improvements include the use of smoother…

量子物理 · 物理学 2009-07-09 Anushree Roy , Chiung-Yuan Lin , U. Mohideen

We comment on progress in measurements of the Casimir force and discuss what is the actual reliability of different experiments. In this connection a more rigorous approach to the usage of such concepts as accuracy, precision, and measure…

量子物理 · 物理学 2015-05-20 G. L. Klimchitskaya , V. M. Mostepanenko

Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and…

量子物理 · 物理学 2009-11-13 Hsiang-Chih Chiu , Chia-Cheng Chang , R. Castillo-Garza , F. Chen , U. Mohideen

We analyse the result of precise measurement of the Casimir force between bodies covered with gold. The values of the parameters used to extrapolate the gold dielectric function to low frequencies are very important and discussed in detail.…

量子物理 · 物理学 2009-11-06 V. B. Svetovoy , M. V. Lokhanin

The measurement of the Casimir force between a large gold coated sphere and single crystal silicon plate is performed with an atomic force microscope. A rigorous statistical comparison of data with theory is done, without use of the concept…

量子物理 · 物理学 2009-11-11 F. Chen , U. Mohideen , G. L. Klimchitskaya , V. M. Mostepanenko

We report an improved precision measurement of the Casimir force using metallic gold surfaces. The force is measured between a large gold coated sphere and flat plate using an Atomic Force Microscope. The use of gold surfaces removes some…

量子物理 · 物理学 2009-11-06 B. W. Harris , F. Chen , U. Mohideen

We compare theory and experiment in the Casimir force measurement between gold surfaces performed with the atomic force microscope. Both random and systematic experimental errors are found leading to a total absolute error equal to 8.5 pN…

量子物理 · 物理学 2009-11-10 F. Chen , G. L. Klimchitskaya , U. Mohideen , V. M. Mostepanenko

Difference between bulk material and deposited film is shown to have an appreciable influence on the Casimir force. Analysis of the optical data on gold films unambiguously demonstrates the sample dependence: the dielectric functions of the…

其他凝聚态物理 · 物理学 2007-05-23 V. B. Svetovoy

A brief review of the recent experimental verifications of the Casimir force between extended bodies is presented. With modern techniques, it now appears feasible to test the force law with 1% precision; I will address the issues relating…

量子物理 · 物理学 2007-05-23 S. K. Lamoreaux

We obtain constraints on non-Newtonian gravity following from the improved precision measurement of the Casimir force by means of atomic force microscope. The hypothetical force is calculated in experimental configuration (a sphere above a…

高能物理 - 唯象学 · 物理学 2008-11-26 M. Bordag , B. Geyer , G. L. Klimchitskaya , V. M. Mostepanenko

We establish strict upper limits for the Casimir interaction between multilayered structures of arbitrary dielectric or diamagnetic materials. We discuss the appearance of different power laws due to frequency-dependent material constants.…

量子物理 · 物理学 2009-11-10 Carsten Henkel , Karl Joulain

This article is divided in three sections. In the first section we briefly review some high precision experiments on the Casimir force, underlying an important aspect of the analysis of the data. In the second section we discuss our recent…

量子物理 · 物理学 2007-05-23 Davide Iannuzzi , Ian Gelfand , Mariangela Lisanti , Federico Capasso

We have used an atomic force microscope to make precision measurements of the Casimir force between a metallized sphere of diameter 196 microns and flat plate. The force was measured for plate-sphere separations from 0.1 to 0.9 microns. The…

光学 · 物理学 2009-09-25 U. Mohideen , Anushree Roy

We have analyzed available optical data for Au in the mid-infrared range which is important for a precise prediction of the Casimir force. Significant variation of the data demonstrates genuine sample dependence of the dielectric function.…

量子物理 · 物理学 2008-11-26 I. Pirozhenko , A. Lambrecht , V. B. Svetovoy

The Casimir force, which results from the confinement of the quantum mechanical zero-point fluctuations of the electromagnetic fields, has received significant attention in recent years for its effect on micro- and nano-scale mechanical…

原子物理 · 物理学 2009-11-13 J. N. Munday , Federico Capasso

The experimental investigation of the Casimir force between a large metallized sphere and semiconductor plate is performed using an atomic force microscope. Improved calibration and measurement procedures permitted reduction in the role of…

量子物理 · 物理学 2009-11-13 F. Chen , U. Mohideen , G. L. Klimchitskaya , V. M. Mostepanenko

A multiple scattering formulation is used to calculate the force, arising from fluctuating scalar fields, between distinct bodies described by $\delta$-function potentials, so-called semitransparent bodies. (In the limit of strong coupling,…

高能物理 - 理论 · 物理学 2008-11-26 Kimball A. Milton , Jef Wagner

We consider the Casimir force including all important corrections to it for the configuration used in a recent experiment employing an atomic force microscope. We calculate the long-range hypothetical forces due to the exchange of light and…

高能物理 - 唯象学 · 物理学 2008-11-26 M. Bordag , B. Geyer , G. L. Klimchitskaya , V. M. Mostepanenko

We compare the results of capacitance measurements in the lens-plane and sphere-plane configurations with theoretical predictions from various models of a spherical surface. It is shown that capacitance measurements are incapable of…