相关论文: A Prototype PCI-based Data Acquisition System for …
In ultraviolet (UV) astronomical observations, photons from the sources are very few compared to the visible or infrared (IR) wavelength ranges. Detectors operating in the UV usually employ a photon-counting mode of operation. These…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The Tile Calorimeter at ATLAS is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the…
A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been…
We characterized the S13360-3050CS Multi-Pixel Photon Counter (MPPC), a silicon photomultiplier (SiPM) manufactured by Hamamatsu Photonics K.K.. Measurements were obtained inside a light tight dark box using 365 nm, 400 nm, 525 nm, 660 nm,…
Microwave reflectometry is a non-intrusive plasma diagnostic tool which is widely applied in many fusion devices. In 2014, the microwave reflectometry on Experimental Advanced Superconducting Tokamak (EAST) had been upgraded to measure…
We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital…
Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
We present an algorithm to optimally process uniformly sampled array image data obtained with a nondestructive readout. The algorithm discards full wells, removes cosmic ray (particle) hits and other glitches, and makes a nearly optimum…
A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…
This paper describes the data acquisition system used for data readout from a segmented detector of reactor antineutrinos with active shielding. Theoretical approach to the data acquisition is described and two possible solutions using QDCs…
Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout…
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions…
The NASA Yardstick design for the Integrated Science Instrument Module (ISIM) utilizes 64 1k x 1k InSb imagers. Since multiple readouts per image are required to remove cosmic ray events and to reduce the readout noise, the implied downlink…
The energy range from a few hundred keV to a few MeV includes important probes such as nuclear gamma-rays and the 511 keV annihilation line. However, compared to X-rays and GeV/TeV gamma-rays, this range suffers from lower sensitivity by…
This paper describes a highly integrated, low power chip solution for ECG signal processing in wearable devices. The chip contains an instrumentation amplifier with programmable gain, a band-pass filter, a 12-bit SAR ADC, a novel QRS…
The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for $0.2 < p_T < 2$ GeV/c in the…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5x5x12 cm^3 in size,…