相关论文: Design and performance of LED calibration system p…
We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in…
We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy…
The optical conductivity of the one-band Hubbard model is calculated using the 'Dynamical Cluster Approximation' implementation of dynamical mean field theory for parameters appropriate to high temperature copper-oxide superconductors. The…
A nematic liquid-crystal cell subject to an electric field created by electrodes held at constant potential is modeled as a variable capacitor in an RC circuit. The state of the system is characterized in terms of the director field in the…
This paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the…
Coulomb crystals of cold trapped ions are a leading platform for the realisation of quantum processors and quantum simulations and, in quantum metrology, for the construction of optical atomic clocks and for fundamental tests of the…
This article documents the characteristics of the high voltage (HV) system of the hadronic calorimeter TileCal of the ATLAS experiment. Such a system is suitable to supply reliable power distribution into particles physics detectors using a…
A method of electronic conductivity measurement is presented. It combines two well known methods of electrochemistry: cyclic voltammetry and chronoamperometry. This DC technique uses the Hebb/Wagner approach to block ionic conduction when…
We demonstrate a blackbody radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…
The purpose of the work presented is the calibration of a lamp filament of tungsten was from electrical measurements that are simple and precise, and for determining the temperature of tungsten against the current intensity value crossing…
Studies of the response of the SiD silicon-tungsten electromagnetic calorimeter (ECal) are presented. Layers of highly granular (13 mm^2 pixels) silicon detectors embedded in thin gaps (~ 1 mm) between tungsten alloy plates give the SiD…
Resistance thermometry provides a time-tested method for taking temperature measurements that has been painstakingly developed over the last century. However, fundamental limits to resistance-based approaches along with a desire to reduce…
Lighting systems based on light-emitting diodes (LEDs) possess many benefits over their incandescent counterparts including longer lifespans, lower energy costs, better quality of light and no toxic elements, all without sacrificing…
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…
This work introduces a thermoreflectance-based system designed to measure the surface temperature field of activated microelectronic devices at submicron spatial resolution with either a laser or a CCD camera. The article describes the…
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a…
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number…
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$…
We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light…