相关论文: The CMS Si-strip Tracker
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…
The Compact Muon Solenoid (CMS) detector at the Large Hadron Collider at CERN is used to study the production of new particles in proton-proton collisions at a center of mass energy of 13.6 TeV. The detector includes a magnet based on a 6 m…
Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of…
The ATLAS experiment at the Large Hadron Collider (LHC) at CERN is currently waiting to record the first collision data in spring 2009. Its muon spectrometer is designed to achieve a momentum resolution of 10% pT(mu) = 1 TeV/c. The…
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…
The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…
The use of a Si pixel-based particle tracking scheme in muSR will, among others, allow measurements using a ten-fold increased stopped muons rate and samples ten times smaller than currently possible. Here we present simulation results to…
The CLIC Tracker Detector (CLICTD) is a monolithic pixelated sensor chip produced in a $180$ nm imaging CMOS process built on a high-resistivity epitaxial layer. The chip, designed in the context of the CLIC tracking detector study,…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…
The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are…
The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important…
The next upgrade of the Large Hadron Collider (LHC) is planned from 2026 when the collider will move to its High Luminosity phase (HL-LHC). The CMS detector needs to be substantially upgraded during this period to exploit the fourfold…
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System…
This article focuses on pioneering work on the performance of the three-dimensional (3D) magnetic field map in the entire volume of the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider at CERN. In the CMS heterogeneous…
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…
The Physics and Data Quality Monitoring (DQM) framework aims at providing a homogeneous monitoring environment across various applications related to data taking at the CMS experiment. In this contribution, the DQM system for the Silicon…
Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation…
The COMET experiment focuses on searching for the direct conversion of a muon into an electron on an aluminum nucleus without emitting a neutrino (so-called $\mu\rightarrow e$ conversion). This conversion violates the lepton flavor…