中文
相关论文

相关论文: Low noise temperature control : application to an …

200 篇论文

We describe a set up for measurements of low frequency (1 mHz < f < 20 Hz) conductance fluctuations in a solid conductor. The set-up uses a five probe a.c. measurement technique and extensive digital signal processing to reach a noise floor…

其他凝聚态物理 · 物理学 2007-05-23 Arindam Ghosh , Swastik Kar , Aveek Bid , A. K. Raychaudhuri

Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing…

We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…

Extraneous thermal motion can limit displacement sensitivity and radiation pressure effects, such as optical cooling, in a cavity-optomechanical system. Here we present an active noise suppression scheme and its experimental implementation.…

光学 · 物理学 2015-06-03 Yi Zhao , Dalziel J. Wilson , Kang-Kuen Ni , H. Jeff Kimble

In this study, we developed a diamond quantum magnetometer based on Ramsey interferometry with a short sensor-to-sample distance. Conventional biomagnetic sensors with ensemble nitrogen-vacancy centers using continuous-wave optically…

A wide variety of applications of microwave cavities, such as measurement and control of superconducting qubits, magnonic resonators, and phase noise filters, would be well served by having a highly tunable microwave resonance. Often this…

仪器与探测器 · 物理学 2020-07-07 T. J. Clark , V. Vadakkumbatt , F. Souris , H. Ramp , J. P Davis

We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 \,\textrm{MHz}$ and exhibits an input referred current noise of…

仪器与探测器 · 物理学 2019-10-29 William Bowden , Alvise Vianello , Richard Hobson

We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors (MKIDs) made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of…

The main purpose of this work was to design, develop and construct a simple, low-cost AC susceptometer to measure large, bulk superconducting samples (up to 32 mm in diameter) in the temperature range 78-120 K. The design incorporates a…

超导电性 · 物理学 2009-11-13 P Laurent , J F Fagnard , B Vanderheyden , N Hari Babu , D A Cardwell , M Ausloos , P Vanderbemden

This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…

仪器与探测器 · 物理学 2016-01-11 Elysée Obame Ndong , Olivier Gallot-Lavallée , Frédéric Aitken

A light-beam-assisted temperature-control system operating within a temperature range from 77 to 180 K is developed for investigating the absorption of electromagnetic waves by high-temperature superconductors in the vicinity of…

超导电性 · 物理学 2019-08-17 M. K. Aliev , G. R. Alimov , I. Kholbaev , T. M. Muminov , B. Olimov , B. Yu. Sokolov , R. R. Usmanov

We propose and test a cryogenic setup comprising dielectric waveguides for mm-wave frequencies in the range of 75-110 GHz and temperatures down to 10 mK. The targeted applications are quantum technologies at millimeter-wave frequencies,…

The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. Recently, the Rydberg electrometer has garnered considerable attention due to its…

量子物理 · 物理学 2023-11-14 Hai-Tao Tu , Kai-Yu Liao , Guo-Dong He , Yi-Fei Zhu , Si-Yuan Qiu , Hao Jiang , Wei Huang , Wu Bian , Hui Yan , Shi-Liang Zhu

This paper discusses an outdoor test facility for the noise characterization of active antenna arrays, using measurement results of array noise temperatures in the order of 50 K for a number of small aperture arrays. The measurement results…

天体物理仪器与方法 · 物理学 2011-10-14 E. E. M. Woestenburg , L. Bakker , M. Ruiter , M. V. Ivashina , R. H. Witvers

We fabricate superconducting ion traps with niobium and niobium nitride and trap single 88Sr ions at cryogenic temperatures. The superconducting transition is verified and characterized by measuring the resistance and critical current using…

Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary…

介观与纳米尺度物理 · 物理学 2024-04-16 Elias Roos Hansen , Ferdinand Kuemmeth , Joost van der Heijden

We present results on ultra low noise YBa$_2$Cu$_3$O$_{7-\delta}$ nano Superconducting QUantum Interference Devices (nanoSQUIDs). To realize such devices, we implemented high quality YBCO nanowires, working as weak links between two…

Far-infrared detectors for future cooled space telescopes require ultra-sensitive detectors with optical noise equivalent powers of order 0.2 aW/\sqrt Hz. This performance has already been demonstrated in arrays of transition edge sensors.…

天体物理仪器与方法 · 物理学 2022-07-01 D J Goldie , S. Withington , C. N. Thomas , P. A. R. Ade , R. V. Sudiwala

The thermometer and thermal control system, for the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) experiment, is described, including the design, testing, and results from the first flight of ARCADE. The…

天体物理学 · 物理学 2009-11-07 D. J. Fixsen , P. G. A. Mirel , A. Kogut , M. Seiffert

We introduce a method, which we here name ``active pre-cooling'' (APC), for removing, just prior to performing a measurement, a large fraction of the deleterious thermal photons that would otherwise occupy the electromagnetic modes of a…

量子物理 · 物理学 2024-12-10 Kuan-Cheng Chen , Mark Oxborrow