相关论文: State Observer for the Fourth-order Model of a Sal…
The problem of imbalance detection in a three-phase power system using a phasor measurement unit (PMU) is considered. A general model for the zero, positive, and negative sequences from a PMU measurement at off-nominal frequencies is…
An adaptive state observer is proposed for a class of overparametrized uncertain linear time-invariant systems without restrictive requirement of their representation in the observer canonical form. It evolves the method of generalized…
In this paper we address the problem of state observation for sensorless control of nonlinear magnetic levitation systems, that is, the regulation of the position of a levitated object measuring only the voltage and current of the…
The article deals with the problem of synthesis of an adaptive observer of state variables of a linear time-varying SISO dynamic system. It is assumed that the control signal and the output variable are measurable. It is assumed that the…
Dynamic state and parameter estimation (DSE) plays a key role for reliably monitoring and operating future, power-electronics-dominated power systems. While DSE is a very active research field, experimental applications of proposed…
Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…
Distribution system and market operators will need or be required to monitor closely distribution systems, due to the presence of multiple actors, such as generating and storage units, as also active loads. The reason for this is the effect…
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by…
The state estimation of continuous-time nonlinear systems in which a subset of sensor outputs can be maliciously controlled through injecting a potentially unbounded additive signal is considered in this paper. Analogous to our earlier work…
Power domination is a graph theoretic model which captures how phasor measurement units (PMUs) can be used to monitor a power grid. Fragile power domination takes into account the fact that PMUs may break or otherwise fail. In this model,…
The power domination problem seeks to determine the minimum number of phasor measurement units (PMUs) needed to monitor an electric power network. We introduce random sensor failure before the power domination process occurs and call this…
Sensors called phasor measurement units (PMUs) are used to monitor the electric power network. The power domination problem seeks to minimize the number of PMUs needed to monitor the network. We extend the power domination problem and…
Having actual models for power system components (such as generators and loads or auxiliary equipment) is vital to correctly assess the power system operating state and to establish stability margins. However, power system operators often…
We address the problem of robust state reconstruction for discrete-time nonlinear systems when the actuators and sensors are injected with (potentially unbounded) attack signals. Exploiting redundancy in sensors and actuators and using a…
Assuming access to synchronized stream of Phasor Measurement Unit (PMU) data over a significant portion of a power system interconnect, say controlled by an Independent System Operator (ISO), what can you extract about past, current and…
Phasor measurement units (PMUs) can be effectively utilized for the monitoring and control of the power grid. As the cyber-world becomes increasingly embedded into power grids, the risks of this inevitable evolution become serious. In this…
A new adaptive observer is proposed for a certain class of nonlinear systems with bounded unknown input and parametric uncertainty. Unlike most existing solutions, the proposed approach ensures asymptotic convergence of the unknown…
In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…
An equivalent circuit formulation for power system analysis was demonstrated to improve robustness of Power Flow and enable more generalized modeling, including that for RTUs (Remote Terminal Units) and PMUs (Phasor Measurement Units).…
Timely recognition of voltage instability is crucial to allow for effective control and protection interventions. Phasor measurements units (PMUs) can be utilized to provide high sampling rate time-synchronized voltage and current phasors…