相关论文: Sixteen Multiple-Amplifier Sensing Charge-Coupled …
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal,…
Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…
The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without…
A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device…
Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device…
We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer…
We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
We present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, $1.35$ Mpix sensors, from a new…
Noise pollution investigation takes advantage of two common methods of diagnosis: measurement using a Sound Level Meter and acoustical imaging. The former enables a detailed analysis of the surrounding noise spectrum whereas the latter is…
Electron Multiplying CCDs (EMCCDs) are used much less often than they might be because of the challenges they offer camera designers more comfortable with the design of slow-scan detector systems. However they offer an entirely new range of…
This paper presents a proof-of-concept demonstration of the Skipper-CCD, a sensor with single-electron counting capability, as a promising technology for implementing an electron-pump-based current source. Relying on its single-electron…
Traditional method for measuring continuous-variable quantum entanglement relies on balanced homodyne detections, which are sensitive to vacuum quantum noise coupled in through losses resulted from many factors such as detector's quantum…
The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by…
Due to the increasing dimension, complexity and cost of the future astronomical surveys, new technologies enabling more compact and simpler systems are required. The development of curved detectors allows to enhance the performances of the…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
Active Pixel Sensor (APS) technology has shown promise for next-generation vertex detectors. This paper discusses the design and testing of two generations of APS chips. Both are arrays of 128 by 128 pixels, each 20 by 20 micro-m. Each…
The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800…
Cluster counting dN/dx is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good pion-kaon separation over a broad momentum range is…