中文
相关论文

相关论文: Coil Reweighting to Suppress Motion Artifacts in R…

200 篇论文

Background: Cardiovascular magnetic resonance imaging (CMR) is a well established imaging tool for diagnosing and managing cardiac conditions. The integration of exercise stress with CMR (ExCMR) can enhance its diagnostic capacity. Despite…

信号处理 · 电气工程与系统科学 2025-04-22 Preethi Chandrasekaran , Chong Chen , Yingmin Liu , Syed Murtaza Arshad , Christopher Crabtree , Matthew Tong , Yuchi Han , Rizwan Ahmad

Cine cardiac magnetic resonance imaging (MRI) is widely used for diagnosis of cardiac diseases thanks to its ability to present cardiovascular features in excellent contrast. As compared to computed tomography (CT), MRI, however, requires a…

图像与视频处理 · 电气工程与系统科学 2020-06-24 Qing Lyu , Hongming Shan , Yibin Xie , Debiao Li , Ge Wang

Respiratory motion can cause strong blurring artifacts in the reconstructed image during MR acquisition. These artifacts become more prominent when use in the presence of undersampled data. Recently, compressed sensing (CS) is developed as…

图像与视频处理 · 电气工程与系统科学 2019-04-10 Abdul Haseeb Ahmed , Ijaz M. Qureshi , Jawad Ali Shah , Hammad Omer

Cine Magnetic Resonance Imaging (MRI) allows for understanding of the heart's function and condition in a non-invasive manner. Undersampling of the $k$-space is employed to reduce the scan duration, thus increasing patient comfort and…

图像与视频处理 · 电气工程与系统科学 2024-02-13 Yuyang Xue , Yuning Du , Gianluca Carloni , Eva Pachetti , Connor Jordan , Sotirios A. Tsaftaris

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who cannot reliably hold…

图像与视频处理 · 电气工程与系统科学 2026-05-21 Mahmut Yurt , Kanghyun Ryu , Zhitao Li , Xucheng Zhu , Xianglun Mao , Martin Janich , Marcus Alley , Kawin Setsompop , John Pauly , Shreyas Vasanawala , Ali Syed

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed…

ECG-gated cine imaging in breath-hold enables high-quality diagnostics in most patients, arrhythmia and inability to hold breath, however, can severely corrupt outcomes. Real-time cardiac MRI in free-breathing leverages robust and faster…

Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several…

Magnetic Resonance Imaging (MRI) is a widely utilized diagnostic tool in clinical settings, but its application is limited by the relatively long acquisition time. As a result, fast MRI reconstruction has become a significant area of…

图像与视频处理 · 电气工程与系统科学 2025-06-09 Lixuan Rao , Xinlin Zhang , Yiman Huang , Tao Tan , Tong Tong

Cardiac magnetic resonance imaging is a valuable non-invasive tool for identifying cardiovascular diseases. For instance, Cine MRI is the benchmark modality for assessing the cardiac function and anatomy. On the other hand, multi-contrast…

图像与视频处理 · 电气工程与系统科学 2023-10-11 George Yiasemis , Nikita Moriakov , Jan-Jakob Sonke , Jonas Teuwen

Real-time cardiac cine MRI does not require ECG gating in the data acquisition and is more useful for patients who can not hold their breaths or have abnormal heart rhythms. However, to achieve fast image acquisition, real-time cine…

图像与视频处理 · 电气工程与系统科学 2020-08-21 Eric Z. Chen , Xiao Chen , Jingyuan Lyu , Yuan Zheng , Terrence Chen , Jian Xu , Shanhui Sun

Good quality of medical images is a prerequisite for the success of subsequent image analysis pipelines. Quality assessment of medical images is therefore an essential activity and for large population studies such as the UK Biobank (UKBB),…

Cine cardiac magnetic resonance (CMR) imaging is recognised as the benchmark modality for the comprehensive assessment of cardiac function. Nevertheless, the acquisition process of cine CMR is considered as an impediment due to its…

图像与视频处理 · 电气工程与系统科学 2024-04-11 Anam Hashmi , Julia Dietlmeier , Kathleen M. Curran , Noel E. O'Connor

In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for…

图像与视频处理 · 电气工程与系统科学 2024-08-19 Jiazhen Pan , Wenqi Huang , Daniel Rueckert , Thomas Küstner , Kerstin Hammernik

Cardiac cine magnetic resonance imaging (MRI) is one of the important means to assess cardiac functions and vascular abnormalities. Mitigating artifacts arising during image reconstruction and accelerating cardiac cine MRI acquisition to…

图像与视频处理 · 电气工程与系统科学 2024-07-03 Xiaoxiang Han , Yang Chen , Qiaohong Liu , Yiman Liu , Keyan Chen , Yuanjie Lin , Weikun Zhang

In real-time (RT) cardiac cine imaging, a stack of 2D slices is collected sequentially under free-breathing conditions. A complete heartbeat from each slice is then used for cardiac function quantification. The inter-slice respiratory…

图像与视频处理 · 电气工程与系统科学 2020-07-10 Chong Chen , Yingmin Liu , Orlando P. Simonetti , Rizwan Ahmad

In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related…

图像与视频处理 · 电气工程与系统科学 2019-06-14 lkay Oksuz , James Clough , Bram Ruijsink , Esther Puyol-Anton , Aurelien Bustin , Gastao Cruz , Claudia Prieto , Daniel Rueckert , Andrew P. King , Julia A. Schnabel

Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan…

Cardiovascular magnetic resonance (CMR) imaging is the gold standard for diagnosing several heart diseases due to its non-invasive nature and proper contrast. MR imaging is time-consuming because of signal acquisition and image formation…

图像与视频处理 · 电气工程与系统科学 2025-04-29 Kian Anvari Hamedani , Narges Razizadeh , Shahabedin Nabavi , Mohsen Ebrahimi Moghaddam

Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization…

图像与视频处理 · 电气工程与系统科学 2023-07-28 Tabita Catalán , Matías Courdurier , Axel Osses , René Botnar , Francisco Sahli Costabal , Claudia Prieto
‹ 上一页 1 2 3 10 下一页 ›