中文
相关论文

相关论文: Optimization of GEM detectors for applications in …

200 篇论文

In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…

仪器与探测器 · 物理学 2007-05-23 V. Peskov , P. Fonte

A high spectral resolution observation of the diffuse X-ray background in the 60 - 1000 eV energy range has been made using an array of thirty-six 1 mm^2 micro-calorimeters flown on a sounding rocket. Detector energy resolution ranged from…

Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier…

仪器与探测器 · 物理学 2015-06-23 I. Israelashvili , M. Cortesi , D. Vartsky , L. Arazi , D. Bar , E. N. Caspi , A. Breskin

The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…

仪器与探测器 · 物理学 2018-01-12 R. C. Roque , H. Natal da Luz , L. F. N. D. Carramate , C. D. R. Azevedo , J. A. Mir , F. D. Amaro

Properties of response functions of room temperature gamma-radiation detectors based on wide band-gap semiconductors are researched using Monte-Carlo method. It is shown that approximate formulas which connect detector sensitivity with…

仪器与探测器 · 物理学 2012-07-24 Alexandr A. Zakharchenko

Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC)…

高能物理 - 实验 · 物理学 2025-01-16 Francesco Toschi , Benedikt Maier , Greta Heine , Torben Ferber , Sebastian Kempf , Markus Klute , Belina von Krosigk

We present new measurements of 27 gamma ray energies ranging from 14 keV to 136 keV, obtained using high-energy-resolution magnetic microcalorimeters for energy-dispersive spectrometry. The spectrometer has eight pixels and achieves an…

The performance of germanium detectors for high-energy $\gamma$-rays was evaluated using a 992-keV resonance in the $^{27}$Al(p, $\gamma$)$^{27}$Si reaction. The measurement was conducted at the RIKEN tandem accelerator. The energy of the…

Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…

Images of resolved 5.9 keV electron tracks produced from $^{55}$Fe X-ray interactions are presented for the first time using an optical readout time projection chamber (TPC). The corresponding energy spectra are also shown, with the FWHM…

仪器与探测器 · 物理学 2024-07-19 N. S. Phan , E. R. Lee , D. Loomba

Cryogenic soft X-ray imaging spectrometers are currently being developed for applications in the fields of Astronomy and material sciences. In this paper we present experiments on optimized single devices, which show measured energy…

超导电性 · 物理学 2018-07-04 G. Brammertz , P. Verhoeve , A. Peacock , D. Martin , N. Rando , R. den Hartog , D. J. Goldie

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…

In this paper, the performances of a type of the domestic THGEM (THick Gaseous Electron Multiplier) working in the Ar/CO2 mixtures are reported in details. This kind of single THGEM can provide the gain range from 100 to 1000, which is very…

In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of developing a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the…

仪器与探测器 · 物理学 2015-06-12 F. Resnati , U. Gendotti , R. Chandra , A. Curioni , G. Davatz , H. Frederich , A. Gendotti , L. Goeltl , R. Jebali , D. Murer , A. Rubbia

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

仪器与探测器 · 物理学 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…

仪器与探测器 · 物理学 2025-05-13 M. Bonesini

Energy dispersive X-ray fluorescence (EDXRF) is a widely used non-destructive technique for micro and trace multi-element analysis of materials. Conventional trials show that using laboratory assisted EDXRF measurements, one can obtain…

材料科学 · 物理学 2021-11-08 Md. Akhlak Alam , M. K. Tiwari , Ayushi Trivedi , Ajay Khooha , A. K. Singh

Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the…

The FREGATE gamma ray detector of HETE-2 is sensitive to photons between 6 and 400 keV. This sensitivity range, extended towards low energies, allows us to explore the emission of GRBs in hard X-rays. We fit the spectra of 23 GRBs with…

天体物理学 · 物理学 2016-08-30 C. Barraud , J. L. Atteia , J. F. Olive , J. P. Dezalay

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…