相关论文: Development of fast-response PPAC with strip-reado…
We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…
We have developed a position-sensitive Parallel Plate Avalanche Counter (PPAC), which has been used as a focal plane detector in the BigRIPS fragment separator and the subsequent RI-beam delivery lines at the RIKEN Nishina Center RI Beam…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
An automatic optimisation procedure is proposed for some operational parameters of a Parallel-Plate Avalanche Counter with Optical Readout, a detector designed for heavy-ion tracking and imaging. Exploiting differentiable programming and…
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the…
We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (gamma*beta=2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard `off the shelf' 4-gap…
A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…
We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position…
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…
We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…
An array of Parallel Plate Avalanche Counters (PPAC) for the detection of heavy ions has been developed. The new device, NIFF (Nuclear Instrument for Fission Fragments), consists of four individual detectors and covers $60\%$ of 2$\pi$. It…
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The…
This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma…
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current…