相关论文: Restoring the saturation response of a PMT using p…
A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half…
The linearity of charge response is an important feature of photomultiplier tubes (PMT) for physics measurements, especially the newly developed 20" MCP-PMT. In this paper, in addition to the traditional method of double light sources, we…
With the expanding reach of physics, xenon-based detectors such as PandaX-4T in the China Jinping Underground Laboratory aim to cover an energy range from sub-keV to multi-MeV. A linear response of the photomultiplier tubes (PMTs) is…
Photomultiplier tubes (PMTs) are widely used in particle experiments for photon detection. PMT waveform analysis is crucial for high-precision measurements of the position and energy of incident particles in liquid scintillator (LS)…
Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light…
Many scintillator based detectors employ a set of photomultiplier tubes (PMT) to observe the scintillation light from potential signal and background events. It is important to be able to count the number of photoelectrons (PE) in the…
Particle may sometimes have energy outside the range of radiation detection hardware so that the signal is saturated and useful information is lost. We have therefore investigated the possibility of using an Artificial Neural Network (ANN)…
We characterize the practical receiver in a wide range of signal intensity for optical wireless communication, from discrete pulse regime to continuous waveform regime. We first propose a statistical non-linear model based on the…
Photomultiplier tubes (PMTs) are widely employed in particle and nuclear physics experiments. The accuracy of PMT waveform reconstruction directly impacts the detector's spatial and energy resolution. A key challenge arises when multiple…
A simplified model is proposed based on the characteristics of the photomultiplier tube (PMT). The Model is compared to the available data, and it successes to reproduce the saturation profile of the PMT. The model also adds clarification…
It is critical to construct an accurate optical model of photomultiplier tubes (PMTs) in many applications to describe the angular and spectral responses of the photon detection efficiency (PDE) of the PMTs in their working media. In this…
To address the Reactor Antineutrino Anomaly (RAA) observed in neutrino experiments, the Reactor Experiment for Neutrino and Exotics (RENE) has been initiated using a liquid scintillation detector. In this study, we investigate the…
We performed photometric calibration of the PhotoMultiplier Tube (PMT) and readout electronics used for the new fluorescence detectors of the Telescope Array (TA) experiment using Rayleigh scattered photons from a pulsed nitrogen laser…
Silicon photomultipliers present saturation effects as they have a limited number of pixels and work in Geiger mode. Their response to light pulses in the nonlinear region is very complex for two reasons: pixel recharging after an avalanche…
Photomultiplier tubes (PMTs) are widely used in particle and nuclear physics experiments. The reconstruction of PMT waveforms is a fundamental task in these experiments, where accurate extraction of photoelectron (PE) multiplicities and…
Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude…
In this article, we show that the collective light-matter strong coupling regime, where $N$ molecular emitters couple to the photon mode of an optical cavity, can be mapped to a quantum impurity model where the photon is the impurity that…
In this work we explore the application of deep neural networks to the optimization of atomic layer deposition processes based on thickness values obtained at different points of an ALD reactor. We introduce a dataset designed to train…
This paper demonstrates a novel method to extract photomultiplier tube (PMT) calibration timing constants in large liquid scintillation detectors from physics data using the machinery of unsupervised deep learning. The approach uses a…
For filter-based magnetographs, the linear calibration method under the weak-field assumption is usually adopted; this leads to magnetic saturation effect in the regions with strong magnetic field. This article explores a new method to…