中文
相关论文

相关论文: Operational Optimization to Maximize Dynamic Range…

200 篇论文

A Kinetic Inductance Traveling Wave amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly Niobium Titanium Nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable…

量子物理 · 物理学 2024-12-16 A. Giachero , M. Vissers , J. Wheeler , L. Howe , J. Gao , J. Austermann , J. Hubmayr , A. Nucciotti , J. Ullom

Microwave impedance microscopy (MIM) is a near-field imaging technique that has been used to visualize the local conductivity of materials with nanoscale resolution across the GHz regime. In recent years, MIM has shown great promise for the…

应用物理 · 物理学 2023-10-03 Leonard Weihao Cao , Chen Wu , Rajarshi Bhattacharyya , Ruolun Zhang , Monica T. Allen

Within this proceeding, we introduce the U-Board platform, a versatile platform for signal generation, acquisition and processing, based on a heterogenous processing architecture. Based on this platform we present a readout for Microwave…

The superconducting materials that make up an MKID have a significant effect on its performance. The $T_\textrm{c}$ and normal state resistivity $\rho_\textrm{N}$ of the film determine the penetration depth $\lambda$ and therefore how much…

天体物理仪器与方法 · 物理学 2020-05-01 Benjamin A. Mazin

The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the…

The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing…

The Habitable Worlds Observatory (HWO) -- a flagship ultraviolet/optical/infrared space telescope recommended by the National Academies' Pathways to Discovery in Astronomy and Astrophysics -- will require detector technologies capable of…

The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The…

The Probe far-Infrared Mission for Astrophysics (PRIMA) is a proposed space observatory which will use arrays of thousands of kinetic inductance detectors (KIDs) to perform low- and moderate-resolution spectroscopy throughout the…

We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on…

仪器与探测器 · 物理学 2014-11-18 R. M. J. Janssen , A. Endo , P. J. de Visser , T. M. Klapwijk , J. J. A. Baselmans

Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the…

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms…

天体物理仪器与方法 · 物理学 2023-04-04 G. Wang , P. S. Barry , T. Cecil , C. L. Chang , J. Li , M. Lisovenko , V. Novosad , Z. Pan , V. G. Yefremenko , J. Zhang

Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance.…

We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical…

仪器与探测器 · 物理学 2016-02-17 G. Coiffard , K-F. Schuster , E. F. C. Driessen , S. Pignard , M. Calvo , A. Catalano , J. Goupy , A. Monfardini

To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs,…

天体物理仪器与方法 · 物理学 2013-09-18 P. Diener , H. G. Leduc , S. J. C. Yates , Y. J. Y. Lankwarden , J. J. A. Baselmans

We have fabricated planar amorphous Indium Oxide superconducting resonators ($T_c\sim2.8$ K) that are sensitive to frequency-selective radiation in the range of 7 to 10 GHz. Those values lay far below twice the superconducting gap that…

We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to…

The CONCERTO millimeter-wave spectral-imaging instrument was deployed on the Atacama Pathfinder EXperiment (APEX), where it acquired science data between April 2021 and May 2023. The instrument features two focal-plane arrays, each composed…

信号处理 · 电气工程与系统科学 2026-04-30 Mounir Abdkrimi , Olivier Rossetto , Olivier Bourrion , Christophe Hoarau , Christophe Vescovi

GroundBIRD is a ground-based experiment for the precise observation of the polarization of the cosmic microwave background (CMB). To achieve high sensitivity at large angular scale, we adopt three features in this experiment: fast rotation…