相关论文: Slice energy spread measurement in the low energy …
An approach to determine the kinetic beam energy at the $10^{-5}$ level is presented, which corresponds to an improvement by more than one order of magnitude compared to conventional methods. Particularly, collinear fluorescence and…
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under…
Numerical and semi-analytical models are presented for photon-enhanced-thermionic-emission (PETE) devices. The models take diffusion of electrons, inhomogeneous photogeneration, and bulk and surface recombination into account. The…
In this work, a combination of cathode retraction and two-slit emittance measurement technique is proposed as an advanced means to individually modify emittance growth components, specifically, rf injector fringe fields, to isolate and…
The energy spread in laser-wakefield accelerators is primarily limited by the energy-chirp introduced during the injection and acceleration processes. Here we propose and demonstrate the use of longitudinal density tailoring to adapt the…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
We present simulations which predict significantly higher laser to X-ray efficiencies than those previously found in high intensity (1e20-1e22 W/cm2) laser-solid simulations. The bremsstrahlung emission is shown to last for 10-100 ps, which…
In this letter we report the preliminary validation of a low-cost paradigm for photovoltaic power generation that utilizes a prismatic Fresnel-like lens to simultaneously concentrate and separate sunlight into continuous laterally spaced…
The photon radiation in the initial state lowers the energy available for the e$^+$e$^-$ collisions; this effect is particularly important at LEP2 energies (above the mass of the Z boson). Being aligned to the beam direction, such initial…
Time-resolved soft-x-ray-diffraction experiments give access to microscopic processes in a broad range of solid-state materials by probing ultrafast dynamics of ordering phenomena. While laboratory-based high-harmonic generation (HHG) light…
A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to…
High peak and average power free-electron lasers (FELs) in the terahertz region (THz) require small diameter, low-emittance, and high voltage electron beams. This paper presents two 1.5-2 MV, 100-200 A, thermionic cathode electron source…
Angle resolved photoelectron spectroscopic measurements have been performed on an insulating cuprate Ca_2CuO_2Cl_2. High resolution data taken along the \Gamma to (pi,pi) cut show an additional dispersive feature that merges with the known…
We demonstrate through high-fidelity particle-in-cell simulations a simple approach for efficiently generating 20+ GeV electron beams with the necessary charge, energy spread, and emittance for use as the injector for an electron arm of a…
We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular X-ray calorimeter made of…
We report a measurement of the inclusive electron energy spectrum for semileptonic decays of B mesons in a data sample of 52 million Y4S -> BBar decays collected with the BABAR detector at the PEP-II asymmetric-energy B-meson factory at…
Photoelectric effect in a Ge-on-Si single-photon avalanche detector (SPAD) at a sub-photon energy in incident pulsed laser radiation is considered in frames of classical electrodynamics of continuous media. It is shown that the energy of…
We describe a self calibrating optical technique that allows to perform absolute measurements of scattering cross sections for the light scattered at extremely small angles. Very good performances are obtained by using a very simple optical…
Besides the designed beam acceleration, the energy of electrons changed by the longitudinal wakefields in a real free-electron laser (FEL) facility, which may degrade FEL performances from the theoretical expectation. In this paper, with…