相关论文: An Extension of Weak-Value Theory for Birefringenc…
Weak value amplification is a classical phenomenon that can enhance the sensitivity of a measurement through clever use of interference. The most well-known paradigm of weak value amplification makes use of a Gaussian pulse, which is…
The technique of almost-balanced weak values amplification (ABWV) was recently proposed [Phys. Rev. Lett. 116: 100803 (2016)]. We demonstrate this technique using a modified Sagnac interferometer, where the counter-propagating beams are…
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams.…
Weak value amplification (WVA) is a metrological protocol that amplifies ultra-small physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the…
Precision measurements of ultra-small linear velocities of one of the mirrors in a Michelson interferometer are performed using two different weak-values techniques. We show that the technique of Almost-Balanced Weak Values (ABWV) offers…
We experimentally realize a great precision enhancement in the small tilt measurement by using a Sagnac interferometer and balanced homodyne detection (BHD) of high-order optical modes, together with the weak value amplification (WVA)…
We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [P. B. Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system…
Experiments based on free space platform have demonstrated that the weak value amplification (WVA) technique can provide high sensitivity and precision for optical sensing and metrology. To promote this technique for real-world…
The precision enhancement is demonstrated in an optical spatial measurement based on weak value amplification (WVA) system and split-like detection, by injecting a TEM$_{10}$ squeezed vacuum beam. It is the first time to experimentally…
In a quantum-noise limited system, weak-value amplification using post-selection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power…
We introduce an ultra-sensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA + interferometry uses weak value amplification of the relative delay between two paths…
We present a weak measurement protocol that permits a sensitive estimation of angular rotations based on the concept of weak-value amplification. The shift in the state of a pointer, in both angular position and the conjugate orbital…
The extraordinary concept of weak value amplification has attracted considerable attention for addressing foundational questions in quantum mechanics and for metrological applications in high precision measurement of small physical…
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134,…
Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak value amplification approach has been developed for measuring ultra-small physical effects, realizing sensitivity that had…
A protocol employing weak values (WVs) to obtain ultra sensitive amplification of weak signals in the context of a solid state setup is proposed. We consider an Aharonov-Bohm interferometer where both the orbital and the spin degrees of…
We investigate the weak measurement experiment demonstrated by Ritchie et al. [N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991)] from the viewpoint of the statistical hypothesis testing for the weak-value…
The amplification obtained using weak values is quantified through a detailed investigation of the signal to noise ratio for an optical beam deflection measurement. We show that for a given deflection, input power and beam radius, the use…
Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror's position…
By choosing more orthogonality between pre-selection and post-selection states, one can significantly improve the sensitivity in the general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing…