中文
相关论文

相关论文: An analytical model for electronic noise in a cryo…

200 篇论文

We have developed preamplifier configurations used to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. We introduce…

天体物理学 · 物理学 2015-06-24 D. Yvon , V. Sushkov

This paper reports the detailed noise characterization, investigation of various noise sources and its mitigation to improve the performance of a cryogenic bolometer detector. The noise spectrum has been measured for a sapphire bolometer…

Thermal Kinetic Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of…

We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $\sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal…

仪器与探测器 · 物理学 2019-04-24 V. V. Zavjalov , A. M. Savin , P. J. Hakonen

We present a cryogenic microwave noise source with a characteristic impedance of 50 $\Omega$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K…

We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor (TES) detectors with an integrated absorber, the other is…

仪器与探测器 · 物理学 2009-11-11 J. W. Appel , M. Galeazzi

A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…

天体物理仪器与方法 · 物理学 2011-09-19 Eric W. Bryerton

We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…

仪器与探测器 · 物理学 2009-10-31 D. Yvon , V. Sushkov , R. Bernard , J. L. Bret , B. Cahan , O. Cloue , O. Maillard , B. Mazeau , J. P. Passerieux , B. Paul , C. Veyssiere

We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…

The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using…

This paper presents an extensive characterization of the low-frequency noise (LFN) at room temperature (RT) and cryogenic temperature (4.2 K) of 40-nm bulk-CMOS transistors. The noise is measured over a wide range of bias conditions and…

应用物理 · 物理学 2024-05-29 Gerd Kiene , Sadik Ilik , Luigi Mastrodomenico , Masoud Babaie , Fabio Sebastiano

We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal…

仪器与探测器 · 物理学 2017-01-13 Archita Hati , Craig W. Nelson , David Pappas , David A. Howe

The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of…

天体物理仪器与方法 · 物理学 2013-01-08 Darcy Barron , Matt Atlas , Brian Keating , Ron Quillin , Nathan Stebor , Brandon Wilson

State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical…

We show that a cryogenic amplifier composed of a homemade GaAs high-electron-mobility transistor (HEMT) is suitable for current-noise measurements in a mesoscopic device at dilution-refrigerator temperatures. The lower noise characteristics…

介观与纳米尺度物理 · 物理学 2021-02-25 Sanghyun Lee , Masayuki Hashisaka , Takafumi Akiho , Kensuke Kobayashi , Koji Muraki

This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a…

仪器与探测器 · 物理学 2026-05-19 Daniil Frolov , Jean-Olivier Plouchart , Utku Soylu

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers,…

Radiation sensors based on the heating effect of the absorbed radiation are typically relatively simple to operate and flexible in terms of the input frequency. Consequently, they are widely applied, for example, in gas detection, security,…

介观与纳米尺度物理 · 物理学 2020-10-02 R. Kokkoniemi , J. -P. Girard , D. Hazra , A. Laitinen , J. Govenius , R. E. Lake , I. Sallinen , V. Vesterinen , P. Hakonen , M. Möttönen

Advances in nanomechanics within recent years have demonstrated an always expanding range of devices, from top-down structures to appealing bottom-up MoS$_2$ and graphene membranes, used for both sensing and component-oriented applications.…

The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large arrays, we…

‹ 上一页 1 2 3 10 下一页 ›