相关论文: Calibration of beam position monitors for high ene…
Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics…
The primary objective of accelerator tuning is to correct its linear optics. This involves adjusting a large set of parameters, such as quadrupole lens gradients and alignment errors, as well as addressing various calibration errors in beam…
In the present work we develop an algorithm for calibrating MEMS sensors, which accounts for the nonorthogonality of the accelerometers' axis, as well as for the constant bias and scaling errors. We derive an explicit formula for computing…
A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without…
Corrections of gradient errors in the interactions regions (IRs) of high energy colliders have traditionally been made by changing the strengths of quadrupoles that are common to both beams, such as the triplet quadrupoles. This article…
We investigate methods to calibrate the non-common path aberrations at an adaptive optics system having a wavefront-correcting device working at an extremely high resolution (larger than 150x150). We use focal-plane images collected…
Visual navigation devices require precise calibration to achieve high-precision localization and navigation, which includes camera and attitude calibration. To address the limitations of time-consuming camera calibration and complex…
A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…
Beam position monitor (BPM) can easily reinforce the handling of beam orbits and measure the absolute beam position [1]. Its data can be used to optimize and correct beam in both first turn and closed orbit mode. In order to set the…
A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…
The beam aperture of a particle accelerator defines the clearance available for the circulating beams and is a parameter of paramount importance for the accelerator performance. At the CERN Large Hadron Collider (LHC), the knowledge and…
The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…
In the Large Hadron Collider, the beam losses are continuously measured for machine protection. By design, most of the particle losses occur in the collimation system, where the particles with high oscillation amplitudes or large momentum…
Low-cost micro-electromechanical accelerometers are widely used in navigation, robotics, and consumer devices for motion sensing and position estimation. However, their performance is often degraded by bias errors. To eliminate…
The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…
Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…
In conventional beam based alignment (BBA) procedures, the relative alignment of a quadrupole to a nearby beam position monitor is determined by finding a beam position in the quadrupole at which the closed orbit does not change when the…
The problem of errors, arising due to finite BPM resolution, in the difference orbit parameters, which are found as a least squares fit to the BPM data, is one of the standard and important problems of accelerator physics. Even so for the…
Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…
The paper focuses on the accuracy improvement of geometric and elasto-static calibration of industrial robots. It proposes industry-oriented performance measures for the calibration experiment design. They are based on the concept of…