中文
相关论文

相关论文: 3D Vessel Reconstruction in OCT-Angiography via De…

200 篇论文

Typical optical coherence tomographic angiography (OCTA) acquisition areas on commercial devices are 3x3- or 6x6-mm. Compared to 3x3-mm angiograms with proper sampling density, 6x6-mm angiograms have significantly lower scan quality, with…

图像与视频处理 · 电气工程与系统科学 2020-06-11 Min Gao , Yukun Guo , Tristan T. Hormel , Jiande Sun , Thomas Hwang , Yali Jia

Accurate 3D representations of cardiac structures allow quantitative analysis of anatomy and function. In this work, we propose a method for reconstructing complete 3D cardiac shapes from segmentations of sparse planes in CT angiography…

计算机视觉与模式识别 · 计算机科学 2026-04-07 Gino E. Jansen , Carolina Brás , R. Nils Planken , Mark J. Schuuring , Berto J. Bouma , Ivana Išgum

Recent studies suggest that early stages of diabetic retinopathy (DR) can be diagnosed by monitoring vascular changes in the deep vascular complex. In this work, we investigate a novel method for automated DR grading based on optical…

图像与视频处理 · 电气工程与系统科学 2022-12-22 Linus Kreitner , Ivan Ezhov , Daniel Rueckert , Johannes C. Paetzold , Martin J. Menten

Optical coherence tomography angiography (OCTA) can non-invasively image the eye's circulatory system. In order to reliably characterize the retinal vasculature, there is a need to automatically extract quantitative metrics from these…

图像与视频处理 · 电气工程与系统科学 2022-07-25 Martin J. Menten , Johannes C. Paetzold , Alina Dima , Bjoern H. Menze , Benjamin Knier , Daniel Rueckert

The purpose of this study is to present a new semi-automated methodology for three-dimensional (3D) reconstruction of coronary arteries and their plaque morphology using Computed Tomography Angiography (CTA) images. The methodology is…

This study is to demonstrate deep learning for automated artery-vein (AV) classification in optical coherence tomography angiography (OCTA). The AV-Net, a fully convolutional network (FCN) based on modified U-shaped CNN architecture,…

图像与视频处理 · 电气工程与系统科学 2020-06-09 Minhaj Alam , David Le , Taeyoon Son , Jennifer I. Lim , Xincheng Yao

Background: Computed Tomography Angiography (CTA) is crucial for cerebrovascular disease diagnosis. Dynamic CTA is a type of imaging that captures temporal information about the We aim to develop and evaluate two segmentation techniques to…

医学物理 · 物理学 2025-02-17 Shrikanth Yadav , Jisoo Kim , Geoffrey Young , Lei Qin

Existing methods to reconstruct vascular structures from a computed tomography (CT) angiogram rely on injection of intravenous contrast to enhance the radio-density within the vessel lumen. However, pathological changes can be present in…

图像与视频处理 · 电气工程与系统科学 2020-02-11 Anirudh Chandrashekar , Ashok Handa , Natesh Shivakumar , Pierfrancesco Lapolla , Vicente Grau , Regent Lee

Eye diseases are common in older Americans and can lead to decreased vision and blindness. Recent advancements in imaging technologies allow clinicians to capture high-quality images of the retinal blood vessels via Optical Coherence…

计算机视觉与模式识别 · 计算机科学 2024-07-23 Jacob Thrasher , Annahita Amireskandari , Prashnna Gyawali

Diabetic Retinopathy (DR), an ocular complication of diabetes, is a leading cause of blindness worldwide. Traditionally, DR is monitored using Color Fundus Photography (CFP), a widespread 2-D imaging modality. However, DR classifications…

Optical coherence tomography angiography (OCTA) is a novel imaging modality that has been widely utilized in ophthalmology and neuroscience studies to observe retinal vessels and microvascular systems. However, publicly available OCTA…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Mingchao Li , Kun Huang , Qiuzhuo Xu , Jiadong Yang , Yuhan Zhang , Zexuan Ji , Keren Xie , Songtao Yuan , Qinghuai Liu , Qiang Chen

Optical Coherence Tomography (OCT) and Optical Coherence Tomography Angiography (OCTA) are key diagnostic tools for clinical evaluation and management of retinal diseases. Compared to traditional OCT, OCTA provides richer microvascular…

图像与视频处理 · 电气工程与系统科学 2025-04-01 Renzhi Tian , Jinjie Wang , Wei Yang , Weizhen Li , Haoran Chen , Yiran Zhu , Chengchang Pan , Honggang Qi

The ultra-wide optical coherence tomography angiography (OCTA) has become an important imaging modality in diabetic retinopathy (DR) diagnosis. However, there are few researches focusing on automatic DR analysis using ultra-wide OCTA. In…

图像与视频处理 · 电气工程与系统科学 2022-10-04 Junlin Hou , Fan Xiao , Jilan Xu , Yuejie Zhang , Haidong Zou , Rui Feng

Targeted diagnosis and treatment plans for patients with coronary artery disease vary according to atherosclerotic plaque component. Coronary CT angiography (CCTA) is widely used for artery imaging and determining the stenosis degree.…

图像与视频处理 · 电气工程与系统科学 2023-08-14 Jun Li , Kexin Li , Yafeng Zhou , S. Kevin Zhou

Digital Subtraction Angiography (DSA) is one of the gold standards in vascular disease diagnosing. With the help of contrast agent, time-resolved 2D DSA images deliver comprehensive insights into blood flow information and can be utilized…

图像与视频处理 · 电气工程与系统科学 2024-05-20 Zhentao Liu , Huangxuan Zhao , Wenhui Qin , Zhenghong Zhou , Xinggang Wang , Wenping Wang , Xiaochun Lai , Chuansheng Zheng , Dinggang Shen , Zhiming Cui

Intracoronary Optical Coherence Tomography (OCT) enables high-resolution visualization of coronary vessel anatomy but presents challenges due to noise, imaging artifacts, and complex tissue structures. This paper proposes a fully automated…

计算机视觉与模式识别 · 计算机科学 2026-02-20 Amal Lahchim , Lambros Athanasiou

Vessel stenosis is a major risk factor in cardiovascular diseases (CVD). To analyze the degree of vessel stenosis for supporting the treatment management, extraction of coronary artery area from Computed Tomographic Angiography (CTA) is…

图像与视频处理 · 电气工程与系统科学 2019-07-30 Yo-Chuan Chen , Yi-Chen Lin , Ching-Ping Wang , Chia-Yen Lee , Wen-Jeng Lee , Tzung-Dau Wang , Chung-Ming Chen

Optical coherence tomography angiography (OCTA) requires high transverse sampling density for visualizing retinal and choroidal capillaries. Low transverse sampling causes resolution degradation, such as the angiograms in wide-field OCTA.…

图像与视频处理 · 电气工程与系统科学 2020-01-09 Ting Zhou , Kang Zhou , Jianlong Yang , Liyang Fang , Yan Hu , Yitian Zhao , Jun Cheng , Xiangping Chen , Shenghua Gao , Jiang Liu

Accurate three-dimensional (3D) reconstruction of guidewire shapes is crucial for precise navigation in robot-assisted endovascular interventions. Conventional 2D Digital Subtraction Angiography (DSA) is limited by the absence of depth…

机器人学 · 计算机科学 2025-06-30 Tianliang Yao , Bingrui Li , Bo Lu , Zhiqiang Pei , Yixuan Yuan , Peng Qi

We propose a novel method for non-rigid 3-D motion correction of orthogonally raster-scanned optical coherence tomography angiography volumes. This is the first approach that aligns predominantly axial structural features like retinal…