中文
相关论文

相关论文: Photon-counting CT with silicon detectors: feasibi…

200 篇论文

In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…

仪器与探测器 · 物理学 2020-08-28 Patrick McCormack , Maurice Garcia-Sciveres , Timon Heim , Benjamin Nachman , Magne Lauritzen

The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of…

仪器与探测器 · 物理学 2021-09-03 Jiaxing Wen , Minghai Yu , Yuchi Wu , Ming Zeng , Bo Zhang , Jirong Cang , Yuge Zhang , Ge Ma , Yue Yang , Wenbo Mo , Zongqing Zhao

The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…

We have developed radiation detectors using the new synthetic diamonds. The diamond detector has an advantage for observations of "low/medium" energy gamma rays as a Compton telescope. The primary advantage of the diamond detector can…

Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 mm-0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this…

医学物理 · 物理学 2024-01-18 Rickard Brunskog , Mats Persson , Zihui Jin , Mats Danielsson

The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2…

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising…

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…

高能物理 - 实验 · 物理学 2009-10-28 Yoshizumi Inoue , Shigetaka Moriyama , Hideyuki Hara , Makoto Minowa , Fumio Shimokoshi

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

An innovative X-ray imaging sensor with intrinsic digital characteristics is presented. It is based on Chromatic Photon Counting technology. The detector is able to count individually the incident X-ray photons and to separate them…

仪器与探测器 · 物理学 2015-06-11 R. Bellazzini , G. Spandre , A. Brez , M. Minuti , M. Pinchera , P. Mozzo

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

仪器与探测器 · 物理学 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the…

仪器与探测器 · 物理学 2015-06-19 D. J. Corvan , G. Sarri , M. Zepf

Further development of quantum emitter based communication and sensing applications intrinsically depends on the availability of robust single-photon detectors. Here, we demonstrate a new generation of superconducting single-photon…

Mid-infrared spectrum is a critical tool for chemical analysis, industrial inspection, environment, and other fields due to its rich chemical bond information. However, the complicated growth or fabrication procedures of existing…

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

天体物理学 · 物理学 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…

仪器与探测器 · 物理学 2021-01-21 Erik Fredenberg , Mats Lundqvist , Bjorn Cederstrom , Magnus Aslund , Mats Danielsson

A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint…

Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers…

The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…

仪器与探测器 · 物理学 2016-10-12 J. J Gomez-Cadenas , J. M. Benlloch-Rodríguez , P. Ferrario , F. Monrabal , J. Rodríguez , J. F. Toledo

3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC upgrade of the ATLAS pixel detector. 3D detectors are already in use today in the ATLAS IBL and AFP experiments. These are…