相关论文: Photon-counting CT with silicon detectors: feasibi…
We report on a new photon-counting detector possessing unprecedented spatial resolution, moderate spectral resolution and high background-rejection capability for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and…
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays…
Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy…
We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…
In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are…
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the…
An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $\gamma$ rays. We report detailed measurements of low-energy spectra from Compton…
The research and development of silicon-based X-ray fluorescence detectors achieved its submicron sensitivity. Its initial use is intended for in-situ beam monitoring at advanced light-source facilities. The effectively functioning…
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and…
We present a gated silicon single photon detector based on a commercially available avalanche photodiode. Our detector achieves a photon detection efficiency of 45\pm5% at 808 nm with 2x 10^-6 dark count per ns at -30V of excess bias and…
Hybrid pixel single-photon-counting detectors have been successfully employed and widely used in Synchrotron radiation X-ray detection. In this paper, the silicon pixel sensors for single X-ray photon detection, which operate in…
A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
We demonstrate an efficient photon number detector for visible wavelengths using a silicon avalanche photodiode. Under subnanosecond gating, the device is able to resolve up to four photons in an incident optical pulse. The detection…
Besides being the foundational material for microelectronics, in optics, crystalline silicon has long been used for making infrared lenses and mirrors. More recently, silicon has become the key material to achieve large-scale integration of…
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…
The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…
The requirements to achieve high detection efficiency (above 50\%) and gigahertz (GHz) frame rate for the proposed 42-keV X-ray free-electron laser (XFEL) at Los Alamos are summarized. Direct detection scenarios using C (diamond), Si, Ge…
Soft X-ray experiments at synchrotron light sources are essential for a wide range of research fields. However, commercially available detectors for this energy range often cannot deliver the necessary combination of quantum efficiency,…