中文
相关论文

相关论文: Moveable Thermometer System in ProtoDUNE

200 篇论文

Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC's is challenging because of its short wavelength, in the VUV range, and…

The detector contains four or more layers of natural Boron absorbing thermal neutrons. Thickness of a layer is 0.4 - 1.2 mg/cm2. The layers are deposited on one or on both sides of a metal surface used as contacts. Between the absorbing…

仪器与探测器 · 物理学 2010-06-10 M. SCHIEBER , O. KHAKHAN

The MicroBooNE experiment is an 85 tonne active mass liquid argon time projection chamber neutrino detector exposed to the on-axis Booster Neutrino Beam (BNB) at Fermilab. One of MicroBooNE's physics goals is the precise measurement of…

高能物理 - 实验 · 物理学 2025-12-24 MicroBooNE collaboration , P. Abratenko , D. Andrade Aldana , L. Arellano , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , A. Barnard , G. Barr , D. Barrow , J. Barrow , V. Basque , J. Bateman , O. Benevides Rodrigues , S. Berkman , A. Bhat , M. Bhattacharya , M. Bishai , A. Blake , B. Bogart , T. Bolton , M. B. Brunetti , L. Camilleri , D. Caratelli , F. Cavanna , G. Cerati , A. Chappell , Y. Chen , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , R. Cross , M. Del Tutto , S. R. Dennis , P. Detje , R. Diurba , Z. Djurcic , K. Duffy , S. Dytman , B. Eberly , P. Englezos , A. Ereditato , J. J. Evans , C. Fang , G. A. Fiorentini Aguirre , B. T. Fleming , W. Foreman , D. Franco , A. P. Furmanski , F. Gao , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , E. Gramellini , P. Green , H. Greenlee , L. Gu , W. Gu , R. Guenette , P. Guzowski , L. Hagaman , M. D. Handley , O. Hen , C. Hilgenberg , G. A. Horton-Smith , A. Hussain , B. Irwin , M. S. Ismail , C. James , X. Ji , J. H. Jo , R. A. Johnson , Y. J. Jwa , D. Kalra , G. Karagiorgi , W. Ketchum , M. Kirby , T. Kobilarcik , N. Lane , J. -Y. Li , Y. Li , K. Lin , B. R. Littlejohn , L. Liu , W. C. Louis , X. Luo , T. Mahmud , C. Mariani , D. Marsden , J. Marshall , N. Martinez , D. A. Martinez Caicedo , S. Martynenko , A. Mastbaum , I. Mawby , N. McConkey , V. Meddage , L. Mellet , J. Mendez , J. Micallef , K. Mistry , T. Mohayai , A. Mogan , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , M. M. Moudgalya , S. Mulleria Babu , D. Naples , A. Navrer-Agasson , N. Nayak , M. Nebot-Guinot , C. Nguyen , J. Nowak , N. Oza , O. Palamara , N. Pallat , V. Paolone , A. Papadopoulou , V. Papavassiliou , H. Parkinson , S. F. Pate , N. Patel , Z. Pavlovic , E. Piasetzky , K. Pletcher , I. Pophale , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , I. Safa , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , E. L. Snider , M. Soderberg , S. Soldner-Rembold , J. Spitz , M. Stancari , J. St. John , T. Strauss , A. M. Szelc , N. Taniuchi , K. Terao , C. Thorpe , D. Torbunov , D. Totani , M. Toups , A. Trettin , Y. -T. Tsai , J. Tyler , M. A. Uchida , T. Usher , B. Viren , J. Wang , M. Weber , H. Wei , A. J. White , S. Wolbers , T. Wongjirad , K. Wresilo , W. Wu , E. Yandel , T. Yang , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang

We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in…

Measuring thermodynamic quantities can be easy or not, depending on the system that is being studied. For a macroscopic object, measuring temperatures can be as simple as measuring how much a column of mercury rises when in contact with the…

量子物理 · 物理学 2015-09-15 O. P. de Sá Neto , M. C. de Oliveira , G. J. Milburn

This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…

仪器与探测器 · 物理学 2016-01-11 Elysée Obame Ndong , Olivier Gallot-Lavallée , Frédéric Aitken

Understanding heat transport is relevant to develop efficient strategies for thermal management in microelectronics for instance, as well as for fundamental science purposes. However, measuring temperatures in nanostructured environments…

Proton resonance frequency (PRF) based MR thermometry is essential for focused ultrasound (FUS) thermal ablation therapies. This work aims to enhance temporal resolution in dynamic MR temperature map reconstruction using an improved deep…

医学物理 · 物理学 2024-07-04 Sijie Xu , Shenyan Zong , Chang-Sheng Mei , Guofeng Shen , Yueran Zhao , He Wang

ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam line…

The nitrogen-vacancy (NV) center in diamond has been recognized as a high-sensitivity nanometer-scale metrology platform. Thermometry has been a recent focus, with attention largely confined to room temperature applications. Thermometry has…

介观与纳米尺度物理 · 物理学 2019-07-31 M. Fukami , C. G. Yale , P. Andrich , X. Liu , F. J. Heremans , P. F. Nealey , D. D. Awschalom

The DUNE experiment is a future long-baseline neutrino oscillation experiment aiming at measuring the neutrino CP-violating phase and establishing the neutrino mass hierarchy, as well as at a rich physics programme from supernovae over…

高能物理 - 实验 · 物理学 2022-11-24 Oliver Lantwin

ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance including a comparison of the…

仪器与探测器 · 物理学 2015-06-22 A. Ereditato , D. Goeldi , S. Janos , I. Kreslo , M. Luethi , C. Rudolf von Rohr , M. Schenk , T. Strauss , M. S. Weber , M. Zeller

We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement…

Remote sensing experiments require high-accuracy, preferably sub-percent, line intensities and in response to this need we present computed room temperature line lists for six symmetric isotopologues of carbon dioxide: $^{13}$C$^{16}$O$_2$,…

We report on compact, gaseous 3He NMR probes for precision magnetometry of magnetic fields B > 0.1 T in the temperature range from ambient temperatures down to 4 Kelvin. The gas is polarized at thermal equilibrium under pressures up to 100…

原子物理 · 物理学 2025-05-26 P. Blümler , M. Fertl , H. -J. Grafe , R. Graf , W. Heil

We report a measurement of the energy-dependent total charged-current cross section $\sigma\left(E_\nu\right)$ for inclusive muon neutrinos scattering on argon, as well as measurements of flux-averaged differential cross sections as a…

高能物理 - 实验 · 物理学 2022-04-13 MicroBooNE Collaboration , P. Abratenko , R. An , J. Anthony , L. Arellano , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , V. Basque , L. Bathe-Peters , O. Benevides Rodrigues , S. Berkman , A. Bhanderi , A. Bhat , M. Bishai , A. Blake , T. Bolton , J. Y. Book , L. Camilleri , D. Caratelli , I. Caro Terrazas , R. Castillo Fernandez , F. Cavanna , G. Cerati , Y. Chen , D. Cianci , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , M. Del Tutto , S. R. Dennis , P. Detje , A. Devitt , R. Diurba , R. Dorrill , K. Duffy , S. Dytman , B. Eberly , A. Ereditato , J. J. Evans , R. Fine , G. A. Fiorentini Aguirre , R. S. Fitzpatrick , B. T. Fleming , N. Foppiani , D. Franco , A. P. Furmanski , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , O. Goodwin , E. Gramellini , P. Green , H. Greenlee , W. Gu , R. Guenette , P. Guzowski , L. Hagaman , O. Hen , C. Hilgenberg , G. A. Horton-Smith , A. Hourlier , R. Itay , C. James , X. Ji , L. Jiang , J. H. Jo , R. A. Johnson , Y. J. Jwa , D. Kalra , N. Kamp , N. Kaneshige , G. Karagiorgi , W. Ketchum , M. Kirby , T. Kobilarcik , I. Kreslo , R. LaZur , I. Lepetic , K. Li , Y. Li , K. Lin , B. R. Littlejohn , W. C. Louis , X. Luo , K. Manivannan , C. Mariani , D. Marsden , J. Marshall , D. A. Martinez Caicedo , K. Mason , A. Mastbaum , N. McConkey , V. Meddage , T. Mettler , K. Miller , J. Mills , K. Mistry , T. Mohayai , A. Mogan , J. Moon , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , J. Mousseau , M. Murphy , D. Naples , A. Navrer-Agasson , M. Nebot-Guinot , R. K. Neely , D. A. Newmark , J. Nowak , M. Nunes , O. Palamara , V. Paolone , A. Papadopoulou , V. Papavassiliou , S. F. Pate , N. Patel , A. Paudel , Z. Pavlovic , E. Piasetzky , I. Ponce-Pinto , S. Prince , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , L. Ren , L. C. J. Rice , L. Rochester , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , G. Scanavini , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , P. Spentzouris , J. Spitz , M. Stancari , J. St. John , T. Strauss , K. Sutton , S. Sword-Fehlberg , A. M. Szelc , W. Tang , K. Terao , C. Thorpe , D. Totani , M. Toups , Y. -T. Tsai , M. A. Uchida , T. Usher , W. Van De Pontseele , B. Viren , M. Weber , H. Wei , Z. Williams , S. Wolbers , T. Wongjirad , M. Wospakrik , K. Wresilo , N. Wright , W. Wu , E. Yandel , T. Yang , G. Yarbrough , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang

Nanomechanical resonators have emerged as sensors with exceptional sensitivities. These sensing capabilities open new possibilities in the studies of the thermodynamic properties in condensed matter. Here, we use mechanical sensing as a…

The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires…

A removable holder carrying a set of miniature temperature sensors inside our Rayleigh-B\'enard convection cylindrical cell has been developed. The sensors should not disturb the temperature and velocity fields of the buoyancy-driven…

流体动力学 · 物理学 2022-04-04 Pavel Hanzelka , Ivan Vlcek , Pavel Urban