中文
相关论文

相关论文: Development of a $^{83\mathrm{m}}$Kr source for th…

200 篇论文

We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$ scintillation…

天体物理仪器与方法 · 物理学 2010-04-14 W. H. Lippincott , S. B. Cahn , D. Gastler , L. W. Kastens , E. Kearns , D. N. McKinsey , J. A. Nikkel

We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid…

仪器与探测器 · 物理学 2009-12-11 L. W. Kastens , S. B. Cahn , A. Manzur , D. N. McKinsey

$^{83m}Kr$ and $^{22}Na$ have been used in calibrating a liquid argon (LAr) detector.$^{83m}Kr$ atoms are produced through the decay of $^{83}Rb$ and introduced into the LAr detector through the circulating purification system. The light…

仪器与探测器 · 物理学 2019-09-06 Weixing Xiong , Mengyun Guan , Changgen Yang , Peng Zhang , Jinchang Liu , Cong Guo , Yuting wei , Youyu Gan , Qin Zhao , Jiajun Li

We report the testing of a charcoal-based Kr-83m source for use in calibrating a low background two-phase liquid xenon detector. Kr-83m atoms produced through the decay of Rb-83 are introduced into a xenon detector by flowing xenon gas past…

仪器与探测器 · 物理学 2014-11-20 L. W. Kastens , S. Bedikian , S. B. Cahn , A. Manzur , D. N. McKinsey

$\rm ^{83m}Kr$, with a short lifetime, is an ideal calibration source for liquid xenon or liquid argon detectors. The $\rm ^{83m}Kr$ isomer can be generated through the decay of $\rm ^{83} Rb$ isotope which is usually produced by proton…

We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in…

仪器与探测器 · 物理学 2021-02-03 Y. Y. Gan , M. Y. Guan , Y. P. Zhang , P. Zhang , C. G. Yang , Q. Zhao , Y. T. Wei , W. X. Xiong

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly…

天体物理仪器与方法 · 物理学 2010-07-23 A. Manalaysay , T. Marrodan Undagoitia , A. Askin , L. Baudis , A. Behrens , A. D. Ferella , A. Kish , O. Lebeda , R. Santorelli , D. Venos , A. Vollhardt

The COHERENT collaboration is deploying a suite of low-energy detectors in a low-background corridor of the ORNL Spallation Neutron Source (SNS) to measure coherent elastic neutrino-nucleus scattering (CEvNS) on an array of nuclear targets…

仪器与探测器 · 物理学 2018-07-01 R. Tayloe

The radioactive isomer $^{83\mathrm{m}}$Kr has many properties that make it very useful for various applications. Its low energy decay products, like conversion, shake-off and Auger electrons as well as X- and $\gamma$-rays are used for…

天体物理仪器与方法 · 物理学 2014-12-24 S. Rosendahl , K. Bokeloh , E. Brown , I. Cristescu , A. Fieguth , C. Huhmann , O. Lebeda , C. Levy , M. Murra , S. Schneider , D. Vénos , C. Weinheimer

Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber.…

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter…

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

仪器与探测器 · 物理学 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^{83\textrm{m}}$Kr calibration applications in the context of…

An electron accelerator in the 100 MeV range, similar to the one used at BNL's Accelerator test Facility, for example, would have some advantages as a calibration tool for water cerenkov or Liquid Argon neutrino detectors. We describe a…

仪器与探测器 · 物理学 2010-04-20 Sebastian White , Vitaly Yakimenko

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

仪器与探测器 · 物理学 2015-01-27 M. Sorel

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization…

A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron…

仪器与探测器 · 物理学 2014-07-11 Sergey Polosatkin , Evgeny Grishnyaev , Alexander Dolgov

Detailed understanding of the ionization process in noble liquid detectors is important for their use in applications such as the search for dark matter and coherent elastic neutrino-nucleus scattering. The response of noble liquid…

We present the preparation and measurement of the radioactive isotope $\rm ^{37}Ar$, which was produced using thermal neutrons from a reactor, as a calibration source for liquid xenon time projection chambers. $\rm ^{37}Ar$ is a low-energy…

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness…

‹ 上一页 1 2 3 10 下一页 ›