相关论文: Effects of misalignment on response uniformity of …
We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…
Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived.…
A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating…
This article presents the development of a cost-effective and efficient electronic module for silicon photomultipliers (SiPM). The electronic module combines essential functionalities, such as a high voltage power supply, a preamplifier,…
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…
Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per…
This study explores the feasibility of using scintillation detectors for muon calorimetry through experiments conducted at CERN's T10 beamline. Results from organic scintillators with varying thicknesses and readout methods, as well as a…
A detailed study of a $5\times5\times5$ cube prototype of the SuperFGD detector was performed using a 730 MeV/$c$ pion beam at the SC-1000 synchrocyclotron (PNPI, Gatchina, Russia). The detector, based on plastic scintillation cubes with…
Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…
Silicon Photomultipliers (SiPM) represent a promising alternative to classical photomultipliers, for instance, for the detection of photons in high energy physics and medical physics. In the present work, electrical characterizations of…
The gain of silicon photomultipliers (SiPMs) increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be readjusted to compensate for temperature changes. We have tested this concept…
Scintillation characteristics of a thallium doped sodium iodide (NaI(Tl)) crystal with a dimension of 0.6 x 0.6 x 2 cm3 are studied by attaching a silicon photomultiplier (SiPM) direct to the crystal over a temperature range from 93 to 300…
We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron-Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned…
The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…
We present in this paper the comparison of methods to measure parameters to characterize a large SiPM of area of about 1 cm$^2$. We also explain the challenges of operating it with continuous light and at room temperature. We present a…
Precise measurement of the absolute light yield (LY) of scintillators has long been limited by systematic effects inherent in realistic readout geometries. Large-angle incidence, multiple reflections inside the optical housing, and…
The gain of silicon photomultipliers (SiPMs) increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be adjusted to compensate temperature changes. We have tested this concept with…
Accurate characterization of quantum yield is crucial to the reconstruction of energy depositions in silicon at the eV scale. This work presents a new method for experimentally calculating quantum yield using vacuum UV-sensitive silicon…