Long-lived, high-frequency phonons are valuable for applications ranging from optomechanics to emerging quantum systems. For scientific as well as technological impact, we seek high-performance oscillators that offer a path towards…
Optical clocks require an ultra-stable laser to probe and precisely measure the frequency of the narrow-linewidth clock transition. We introduce a portable ultraviolet (UV) laser system for use in an aluminum quantum logic clock,…
We describe a compact ultra-high vacuum (UHV) scanning tunneling microscope (STM) system that does not need any external supply of cooling liquids. It achieves temperatures down to 1.5 K and a z-noise down to 300 fmRMS for the frequency…
We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency…
Carrier-envelope phase stabilization of optical pulses enables exquisitely precise measurements by way of direct optical-frequency synthesis, absolute optical-to-microwave phase conversion, and control of ultrafast waveforms. We report such…
Ultrastable lasers serve as the backbone for some of the most advanced scientific experiments today and enable the ability to perform atomic spectroscopy and laser interferometry at the highest levels of precision possible. With the recent…
The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the…
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a…
Controlling the Stark perturbation from ambient thermal radiation is key to advancing the performance of many atomic frequency standards, including state-of-the-art optical lattice clocks (OLCs). We demonstrate a cryogenic OLC that utilizes…
Mm and sub-mm waves polarimetry is the new frontier of research in Cosmic Microwave Background and Interstellar Dust studies. Polarimeters working in the IR to MM range need to be operated at cryogenic temperatures, to limit the systematic…
We present a cryogenic setup where an optical Fabry-Perot resonator is coupled to a single-mode optical fiber with coupling efficiency above 90% at mK temperatures without realignment during cooling down. The setup is prealigned at room…
We have stabilized an external cavity diode laser to a whispering gallery mode resonator formed by a protrusion of a single-crystal magnesiumdifluoride cylinder. The cylinder's compact dimensions (<1 cm^3) reduce the sensitivity to…
A compact cryogenic calibration target is presented that has a peak diffuse reflectance, $R \le 0.003$, from $800-4,800\,{\rm cm}^{-1}$ $(12-2\,\mu$m). Upon expanding the spectral range under consideration to $400-10,000\,{\rm cm}^{-1}$…
We demonstrate voltage-tunable thermo-optic bi- and tri-stability in silicon photonic microring resonators with lateral p-i-n junctions and present a technique for characterizing the thermo-optic transient response of integrated optical…
Cryogenics is a pivotal aspect in the development of quantum technologies. Closed-cycle devices have recently emerged as an environmentally friendly and low-maintenance alternative to liquid helium cryostats. Yet the larger level of…
Resistance thermometry provides a time-tested method for taking temperature measurements. However, fundamental limits to resistance-based approaches has produced considerable interest in developing photonic temperature sensors to leverage…
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW…
We consider thermo-optic hysteresis in a silicon structure supporting bound state in the continuum. Taking into account radiative heat transfer as a major cooling mechanism we constructed a non-linear model describing the optical response.…
We present a cryogenic microwave noise source with a characteristic impedance of 50 $\Omega$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K…
The optical properties of the superconducting K$_{0.8}$Fe$_{1.7}$(Se$_{0.73}$S$_{0.27}$)$_2$ single crystals with a critical temperature $T_c\approx 26$ K have been measured in the {\it ab} plane in a wide frequency range using both…