中文
相关论文

相关论文: Security Measures for Grids against Rank-1 Undetec…

200 篇论文

Sensors such as phasor measurement units (PMUs) endowed with GPS receivers are ubiquitously installed providing real-time grid visibility. A number of PMUs can cooperatively enable state estimation routines. However, GPS spoofing attacks…

系统与控制 · 计算机科学 2018-04-27 Paresh Risbud , Nikolaos Gatsis , Ahmad Taha

The Phasor Measurement Unit (PMU) is an important metering device for smart grid. Like any other Intelligent Electronic Device (IED), PMUs are prone to various types of cyberattacks. However, one form of attack is unique to the PMU, the…

系统与控制 · 电气工程与系统科学 2023-09-14 Imtiaj Khan , Virgilio Centeno

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…

系统与控制 · 电气工程与系统科学 2023-04-18 Saptarshi Ghosh , Murali Sankar Venkatraman , Shehab Ahmed , Charalambos Konstantinou

Many operations in power grids, such as fault detection and event location estimation, depend on precise timing information. In this paper, a novel Time Synchronization Attack (TSA) is proposed to attack the timing information in smart…

密码学与安全 · 计算机科学 2012-04-03 Zhenghao Zhang , Shuping Gong , Aleksandar D. Dimitrovski , Husheng Li

Many operations in power grids, such as fault detection and event location estimation, depend on precise timing information. In this paper, a novel time stamp attack (TSA) is proposed to attack the timing information in smart grid. Since…

密码学与安全 · 计算机科学 2012-01-13 Shuping Gong , Zhenghao Zhang , Husheng Li , Aleksandar D. Dimitrovski

Consider the problem of mitigating the impact on data integrity of phasor measurement units (PMUs) given a GPS spoofing attack. We present a sparse error correction framework to treat PMU measurements that are potentially corrupted due to a…

信号处理 · 电气工程与系统科学 2021-01-19 Shashini De Silva , Jinsub Kim , Eduardo Cotilla-Sanchez , Travis Hagan

In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…

系统与控制 · 计算机科学 2018-06-08 Y. Shi , H. D. Tuan , A. A. Nasir , T. Q. Duong , H. V. Poor

The Phasor measurement unit (PMU) measurements are mandatory to monitor the power system's voltage stability margin in an online manner. Monitoring is key to the secure operation of the grid. Traditionally, online monitoring of voltage…

系统与控制 · 电气工程与系统科学 2024-12-20 Kishan Prudhvi Guddanti , Amarsagar Reddy Ramapuram Matavalam , Yang Weng

Prior research has demonstrated that global positioning system (GPS) spoofing attacks on phasor measurement units (PMUs) can cripple power system operation. This paper provides an experimental evidence of the feasibility of such an attack…

密码学与安全 · 计算机科学 2021-10-08 Fakhri Saadedeen , Anamitra Pal

Physical security of power networks under power injection attacks that alter generation and loads is studied. The system operator employs Phasor Measurement Units (PMUs) for detecting such attacks, while attackers devise attacks that are…

最优化与控制 · 数学 2016-10-20 Yue Zhao , Andrea Goldsmith , H. Vincent Poor

Phasor measurement units (PMUs) can be effectively utilized for the monitoring and control of the power grid. As the cyber-world becomes increasingly embedded into power grids, the risks of this inevitable evolution become serious. In this…

系统与控制 · 计算机科学 2016-05-23 Ahmad F. Taha , Junjian Qi , Jianhui Wang , Jitesh H. Panchal

Big data analytic applications using phasor measurements help improve the situation awareness of grid operators to better operate and control the system. Phasor measurement unit (PMU) data from actual grids is viewed as highly confidential…

系统与控制 · 电气工程与系统科学 2019-09-10 Ti Xu , Hanyue Li , Adam B. Birchfield , Thomas J. Overbye

Synchrophasor technology is an emerging and developing technology for monitoring and control of wide area measurement systems (WAMS). In an elementary WAMS, two identical phasors measured at two different locations have difference in the…

信号处理 · 电气工程与系统科学 2025-04-15 Nisarg Trivedi

This paper studies the vulnerability of phasor measurement units (PMUs) to false data injection (FDI) attacks. Prior work demonstrated that unobservable FDI attacks that can bypass traditional bad data detectors based on measurement…

系统与控制 · 计算机科学 2017-05-08 Jiazi Zhang , Zhigang Chu , Lalitha Sankar , Oliver Kosut

Due to the vulnerability of civilian global positioning system (GPS) signals, the accuracy of phasor measurement units (PMUs) can be greatly compromised by GPS spoofing attacks (GSAs), which introduce phase shifts into true phase angle…

系统与控制 · 电气工程与系统科学 2020-02-26 Ying Zhang , Jianhui Wang , Jianzhe Liu

Phasor measurement units (PMUs) are integrated to the transmission networks under the smart grid umbrella. The observability of PMUs is geographically limited due to their high cost in integration. The measurements of PMUs can be…

系统与控制 · 计算机科学 2017-06-12 HyungSeon Oh

A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the…

系统与控制 · 计算机科学 2018-09-12 Mahdi Jamei , Anna Scaglione , Sean Peisert

With the proposition to install a large number of phasor measurement units (PMUs) in the future power grid, it is essential to provide robust communications infrastructure for phasor data across the network. We make progress in this…

信息论 · 计算机科学 2015-01-05 K. G. Nagananda , Shalinee Kishore , Rick S. Blum

Large-scale blackouts that have occurred in the past few decades have necessitated the need to do extensive research in the field of grid security assessment. With the aid of synchrophasor technology, which uses phasor measurement unit…

系统与控制 · 电气工程与系统科学 2019-09-11 Anubhav Nath , Reetam Sen Biswas , Anamitra Pal

The GPS is vulnerable to GPS spoofing attack (GSA), which leads to disorder in time and position results of the GPS receiver. In power grids, phasor measurement units (PMUs) use GPS to build time-tagged measurements, so they are susceptible…

系统与控制 · 电气工程与系统科学 2023-09-12 Mohammad Sabouri , Sara Siamak , Maryam Dehghani , Mohsen Mohammadi , Mohammad Hassan Asemani