相关论文: Optimal Placement of Limited PMUs for Transmission…
The optimal PMU locations to collect voltage phase angle measurements for detecting line outages in wide-area transmission networks are investigated. The problem is established as one of maximizing the minimum distance among the voltage…
Real-time transmission line outage detection is difficult because of partial phasor measurement unit (PMU) deployment and varying outage signal strength. Existing detection approaches focus on monitoring PMU-measured nodal algebraic states,…
We consider the problem of identifying a single line outage in a power grid by using data from phasor measurement units (PMUs). When a line outage occurs, the voltage phasor of each bus node changes in response to the change in network…
The use of phasor angle measurements provided by phasor measurement units (PMUs) in fault detection is regarded as a promising method in identifying locations of power line outages. However, communication errors or system malfunctions may…
Phasor measurement units (PMUs) create ample real-time monitoring opportunities for modern power systems. Among them, line outage detection and identification remains a crucial but challenging task. Current works on outage identification…
This paper introduces an algorithm able to detect and localize the occurrance of a fault in an Active Distribution Network, using the measurements collected by Phasor Measurement Units (PMUs). First, a basic algorithm that works under the…
Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a…
In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…
The growing integration of distributed energy resources (DERs) in urban distribution grids raises various reliability issues due to DER's uncertain and complex behaviors. With a large-scale DER penetration, traditional outage detection…
The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is…
We consider a power transmission system monitored with Phasor Measurement Units (PMUs) placed at significant, but not all, nodes of the system. Assuming that a sufficient number of distinct single-line faults, specifically pre-fault state…
To provide real-time visibility of physics-based states, phasor measurement units (PMUs) are deployed throughout power networks. PMU data enable real-time grid monitoring and control -- and are essential in transitioning to smarter grids.…
The goal of this paper is to study the impact of the dynamic nature of bus voltage magnitudes and phase angles, which constitute the state of the power system, on the phasor measurement unit (PMU) placement problem. To facilitate this…
Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…
This paper considers the problem of fault detection and localization in active distribution networks using PMUs. The proposed algorithm consists in computing a set of weighted least squares state estimates whose results are used to detect,…
Accurate topology information is critical for effective operation of power distribution networks. Line outages change the operational topology of a distribution network. Hence, outage detection is an important task. Power distribution…
Since transmission lines are crucial links in the power system, one line outage event may bring about interruption or even cascading failure of the power system. If a quick and accurate line outage detection and localization can be…
Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…
This paper proposes a method of identifying single line outages in power systems based on phasor measurement unit (PMU) measurements and ac power flow models. In addition to the main identification algorithm, a rejection filter is…
In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…