相关论文: High Resolution and High Precision Beam Profile Mo…
We describe a setup and procedures for contactless optical 3D-metrology of silicon micro-strip sensors. Space points are obtained by video microscopy and a high precision XY-table. The XY-dimensions are obtained from the movement of the…
We present recent beam data from a new design of a profile monitor for proton beams at Fermilab. The monitors, consisting of grids of segmented Ti foils 5micrometers thick, are secondary-electron emission monitors (SEM's). We review data on…
We developed a beam telescope system comprising five layers of 300-$\mu$m-thick INTPIX4NA monolithic pixel sensors with each pixel size of 17 $\mu$m square. The sensors were fabricated using silicon-on-insulator (SOI) technology. The…
For some synchrotron light source beamline applications, a round beam is preferable to a flat one. A conventional method of obtaining round beam in an electron storage ring is to shift its tune close to a linear difference resonance. The…
The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics.…
The power of the proton beam of a high-power spallation neutron source generally ranges from 100 kW to several MW. The distribution of the power density of the beam on the target is critical for the stable operation of the high-power…
Advanced particle acceleration methods have produced high-peak-current ion beams with broad energy spread and complex spatial distribution. There is an urgent need to develop online spatial-resolved energy spectrometers for high-energy…
We report the development of a fast position-sensitive laser beam detector with a bandwidth that exceeds currently available detectors. The detector uses a fiber-optic bundle that spatially splits the incident beam, followed by a fast…
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…
We developed an electron beam size monitor for extremely small beam sizes. It uses a laser interference fringe for a scattering target with the electron beam. Our target performance is < 2 nm systematic error for 37 nm beam size and < 10%…
We conduct a detailed measurement and analysis of a hadron beam in five-dimensional phase space at the Spallation Neutron Source Beam Test Facility. The measurement's resolution and dynamic range are sufficient to image sharp,…
We have built and tested a compact, low-cost, but very-high-performance astronomical polarimeter based on a continuously rotating half-wave plate and a high-speed imaging detector. The polarimeter is suitable for small telescopes up to ~1 m…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
The performance and safe operation of a particle accelerator is closely connected to the transverse emittance of the beams it produces. For this reason many techniques have been developed over the years for monitoring the transverse…
Purpose: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron and synchrocyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for…
A conventional method to determine beam parameters is using the profile measurements and converting them into the values of twiss parameters and beam emittance at a specified position. The beam information can be used to improve transverse…
AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor (MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging…
In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…