中文
相关论文

相关论文: Optical Response of Lumped-Element Kinetic-Inducta…

200 篇论文

Lumped-element kinetic inductance detectors(LEKIDs) have recently shown considerable promise as direct absorption mm-wavelength detectors for astronomical applications. One major research thrust within the N\'eel Iram Kids Array (NIKA)…

天体物理仪器与方法 · 物理学 2019-08-13 M. Roesch , A. Benoit , A. Bideaud , N. Boudou , M. Calvo , A. Cruciani , S. Doyle , H. G. Leduc , A. Monfardini , L. Swenson , S. Leclercq , P. Mauskopf , K. F. Schuster

With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance…

In this paper, we investigate the single photon response from the reflection of the Microwave Kinetic Inductance Detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with…

天体物理仪器与方法 · 物理学 2024-06-17 Jie Hu , Faouzi Boussaha , Paul Nicaise , Christine Chaumont , Maria Appavou , Viet Dung Pham , Michel Piat

Kinetic Inductance Detectors (KID) are now routinely used in ground-based telescopes. Large arrays, deployed in formats up to kilopixels, exhibit state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on the IRAM…

This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction…

天体物理仪器与方法 · 物理学 2016-07-13 A. Catalano , A. Benoit , O. Bourrion , M. Calvo , G. Coiffard , A. D'Addabbo , J. Goupy , H. Le Sueur , J. Macìas-Pérez , A. Monfardini

The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and…

Lumped-element kinetic inductance detectors (LEKIDs) are an attractive technology for millimeter-wave observations that require large arrays of extremely low-noise detectors. We designed, fabricated and characterized 64-element (128 LEKID)…

We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium,…

Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large…

天体物理仪器与方法 · 物理学 2023-03-29 Usasi Chowdhury , Florence Levy-Bertrand , Martino Calvo , Johannes Goupy , Alessandro Monfardini

Superconducting radiation detectors typically exhibit detection and single photon sensitivity limited to the mid infrared wavelength range. Extending their detection capabilities into the far infrared range (>10 um) requires careful…

We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to…

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can…

天体物理仪器与方法 · 物理学 2012-07-12 O. Bourrion , C. Vescovi , J. L. Bouly , A. Benoit , M. Calvo , L. Gallin-Martel , J. F. Macias-Perez , A. Monfardini

We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited…

One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and…

天体物理仪器与方法 · 物理学 2021-08-31 S. Shu , M. Calvo , J. Goupy , S. Leclercq , A. Catalano , A. Bideaud , A. Monfardini , E. F. C. Driessen

The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon)…

Future space-based far infra-red astronomical observations require background limited detector sensitivities and scalable focal plane array solutions to realise their vast potential in observation speed. In this work, a focal plane array of…

This work presents Ti/Al bi-layer Microwave Kinetic Inductance Detectors (MKIDs) based on lens-coupled spiral absorbers as the quasi-optical coupling mechanism for millimeter-wavelength radiation detection. From simulations, the…

The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called…

The electronic structure and optical response of electrically gated bilayer graphene are studied by first-principles approaches. We have obtained the induced band gap that is in good agreement with experiment when the applied electric field…

介观与纳米尺度物理 · 物理学 2015-03-13 Li Yang

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good…

天体物理仪器与方法 · 物理学 2016-02-15 L. Bisigello , S. J. C. Yates , V. Murugesan , J. J. A. Baselmans , A. M. Baryshev
‹ 上一页 1 2 3 10 下一页 ›