中文
相关论文

相关论文: Electrometer calibration with sub-part-per-million…

200 篇论文

An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…

仪器与探测器 · 物理学 2020-12-03 M. R. Hoeferkamp , J. S. T. Wickramasinghe , A. Grummer , I. Rajen , S. Seidel

The Very Large Area Gamma-ray Space Telescope Pathfinder (VLAST-P), as the technology validation satellite for the VLAST mission, is designed to observe high-energy solar bursts on orbit. The CsI electromagnetic calorimeter (ECAL) is one of…

An ideal phase-preserving linear amplifier is a deterministic device that adds to an input signal the minimal amount of noise consistent with the constraints imposed by quantum mechanics. A noiseless linear amplifier takes an input coherent…

量子物理 · 物理学 2013-10-04 Shashank Pandey , Zhang Jiang , Joshua Combes , Carlton M. Caves

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout…

仪器与探测器 · 物理学 2013-12-23 K. Abe , Y. Hayato , T. Iida , K. Iyogi , J. Kameda , Y. Kishimoto , Y. Koshio , Ll. Marti , M. Miura , S. Moriyama , M. Nakahata , Y. Nakano , S. Nakayama , Y. Obayashi , H. Sekiya , M. Shiozawa , Y. Suzuki , A. Takeda , Y. Takenaga , H. Tanaka , T. Tomura , K. Ueno , R. A. Wendell , T. Yokozawa , T. J. Irvine , H. Kaji , T. Kajita , K. Kaneyuki , K. P. Lee , Y. Nishimura , K. Okumura , T. McLachlan , L. Labarga , E. Kearns , J. L. Raaf , J. L. Stone , L. R. Sulak , S. Berkman , H. A. Tanaka , S. Tobayama , M. Goldhaber , K. Bays , G. Carminati , W. R. Kropp , S. Mine , A. Renshaw , M. B. Smy , H. W. Sobel , K. S. Ganezer , J. Hill , W. E. Keig , J. S. Jang , J. Y. Kim , I. T. Lim , N. Hong , T. Akiri , J. B. Albert , A. Himmel , K. Scholberg , C. W. Walter , T. Wongjirad , T. Ishizuka , S. Tasaka , J. G. Learned , S. Matsuno , S. N. Smith , T. Hasegawa , T. Ishida , T. Ishii , T. Kobayashi , T. Nakadaira , K. Nakamura , K. Nishikawa , Y. Oyama , K. Sakashita , T. Sekiguchi , T. Tsukamoto , A. T. Suzuki , Y. Takeuchi , K. Huang , K. Ieki , M. Ikeda , T. Kikawa , H. Kubo , A. Minamino , A. Murakami , T. Nakaya , M. Otani , K. Suzuki , S. Takahashi , Y. Fukuda , K. Choi , Y. Itow , G. Mitsuka , M. Miyake , P. Mijakowski , R. Tacik , J. Hignight , J. Imber , C. K. Jung , I. Taylor , C. Yanagisawa , Y. Idehara , H. Ishino , A. Kibayashi , T. Mori , M. Sakuda , R. Yamaguchi , T. Yano , Y. Kuno , S. B. Kim , B. S. Yang , H. Okazawa , Y. Choi , K. Nishijima , M. Koshiba , Y. Totsuka , M. Yokoyama , K. Martens , M. R. Vagins , J. F. Martin , P. de Perio , A. Konaka , M. J. Wilking , S. Chen , Y. Heng , H. Sui , Z. Yang , H. Zhang , Y. Zhenwei , K. Connolly , M. Dziomba , R. J. Wilkes

Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the…

仪器与探测器 · 物理学 2025-03-06 Shunyi Liang , Juncheng Liang , Kezhu Song , Yijie Jiang , Zhijie Yang

In order to make a unified treatment for estimation problems of a very small noise or a very weak signal in a quantum process, we introduce the notion of a low-noise quantum channel with one noise parameter. It is known in several examples…

量子物理 · 物理学 2010-04-28 Masahiro Hotta , Tokishiro Karasawa , Masanao Ozawa

A diverse array of science goals require accurate flux calibration of observations with the Atacama Large Millimeter/Submillimeter array (ALMA), however, this goal remains challenging due to the stochastic time-variability of the ``grid''…

天体物理仪器与方法 · 物理学 2020-11-25 Logan Francis , Doug Johnstone , Gregory Herczeg , Todd R. Hunter , Daniel Harsono

This paper derives an a posteriori error estimator for the nonlinear first-order optimality conditions associated with the electrically and flexoelectrically coupled Frank-Oseen model of liquid crystals, building on previous results for…

数值分析 · 数学 2026-04-13 J. H. Adler , D. B. Emerson

We describe the Submillimeter Array (SMA) Polarimeter, a polarization converter and feed multiplexer installed on the SMA. The polarimeter uses narrow-band quarter-wave plates to generate circular polarization sensitivity from the…

天体物理学 · 物理学 2009-11-13 Daniel P. Marrone , Ramprasad Rao

The photometric errors of the external calibrator for the FIRAS instrument on the COBE are smaller than the measurement errors on the cosmic microwave background (CMBR) spectrum (typically 0.02 MJy/sr, 1 sigma), and smaller than 0.01% of…

天体物理学 · 物理学 2009-10-31 J. C. Mather , D. J. Fixsen , R. A. Shafer , C. Mosier , D. T. Wilkinson

We have developed a new method for fabrication of ultra-low noise silver-silver chloride (Ag-AgCl) reference electrode with dramatically high stability, useful in biomedical precise measurements. Low noise level and high stability are the…

化学物理 · 物理学 2019-03-26 Behnoush Rostami , Seyed Iman Mirzaei , Atieh Zamani , A. Simchi , Mehdi Fardmanesh

We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated…

仪器与探测器 · 物理学 2016-10-12 E. Mykkänen , J. S. Lehtinen , A. Kemppinen , C. Krause , D. Drung , J. Nissilä , A. J. Manninen

Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present a convenient calibration scheme and use it to accurately measure the total gain and noise temperature of an…

The activities towards the fabrication and test of a 1 m3 semi-digital hadronic calorime- ter are reviewed. The prototype sampling planes would consist of 1 m2 Micromegas chambers with 1 cm2 granularity and embedded 2 bits readout suitable…

Compact interferometers, called phasemeters, make it possible to operate over a large range while ensuring a high resolution. Such performance is required for the stabilization of large instruments dedicated to experimental physics such as…

天体物理仪器与方法 · 物理学 2018-12-03 Jennifer Watchi , Sam Cooper , Binlei Ding , Conor M. Mow-Lowry , Christophe Collette

We present the design of a Faraday cup-like charged particle detector in a four quadrant configuration aimed at facilitating the alignment of low-intensity beams of exotic particles. The device is capable of assessing the current on the…

Recent advances in precise phasor measurement units are enabling new approaches to estimate distribution and transmission grid parameters in real-time. In this paper, we investigate voltage and current phasor measurement requirements to…

系统与控制 · 电气工程与系统科学 2026-05-04 Norak Rin , Iman Shames , Ian Petersen , Elizabeth Ratnam

This article is present high precision multiwave rectifier circuit operating in low voltage plus or minus 1.5 Volt current modes by CMOS technology 0.5 \mum, receive input and give output in current mode, respond at high frequency period.…

其他计算机科学 · 计算机科学 2010-01-14 Bancha Burapattanasiri

The calibration of modern radio interferometers is a significant challenge, specifically at low frequencies. In this perspective, we propose a novel iterative calibration algorithm, which employs the popular sparse representation framework,…

天体物理仪器与方法 · 物理学 2016-06-06 Martin Brossard , Mohamed Nabil El Korso , Marius Pesavento , Rémy Boyer , Pascal Larzabal