中文
相关论文

相关论文: Maunakea Spectroscopic Explorer (MSE) - The Prime …

200 篇论文

The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph currently in manufacturing, assembly and integration phase. MUSE has a field of 1x1 arcmin2 sampled at 0.2x0.2 arcsec2 and is…

Context. The Spectroscopy Made Easy (SME) package has become a popular tool for analyzing stellar spectra, often in connection with large surveys or exoplanet research. SME has evolved significantly since it was first described in 1996, but…

天体物理仪器与方法 · 物理学 2016-12-21 Nikolai Piskunov , Jeff A. Valenti

This article presents research work on a spectroscopic survey telescope. Our idea is as follows: for such a telescope, a pure reflecting optical system is designed, which should have an aperture and a field of view (FOV) both as large as…

天体物理仪器与方法 · 物理学 2024-03-20 Ding-qiang Su , Hua Bai , Xiangyan Yuan , Xiangqun Cui

With the advent of infrared long-baseline interferometers with more than two telescopes, both the size and the completeness of interferometric data sets have significantly increased, allowing images based on models with no a priori…

天体物理仪器与方法 · 物理学 2015-05-28 Stéphanie Renard , Eric Thiébaut , Fabien Malbet

The Multi Unit Spectroscopic Explorer (MUSE) is an integral field spectrograph on the Very Large Telescope Unit Telescope 4, capable of laser guide star assisted and tomographic adaptive optics using the GALACSI module. Its observing…

Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2m Subaru telescope on the summit of Maunakea in Hawaii. A team of scientists from Japan, Taiwan and Princeton University is using HSC to carry out a…

天体物理仪器与方法 · 物理学 2018-03-16 H. Aihara , N. Arimoto , R. Armstrong , S. Arnouts , N. A. Bahcall , S. Bickerton , J. Bosch , K. Bundy , P. L. Capak , J. H. H. Chan , M. Chiba , J. Coupon , E. Egami , M. Enoki , F. Finet , H. Fujimori , S. Fujimoto , H. Furusawa , J. Furusawa , T. Goto , A. Goulding , J. P. Greco , J. E. Greene , J. E. Gunn , T. Hamana , Y. Harikane , Y. Hashimoto , T. Hattori , M. Hayashi , Y. Hayashi , K. G. Hełminiak , R. Higuchi , C. Hikage , P. T. P. Ho , B. -C. Hsieh , K. Huang , S. Huang , H. Ikeda , M. Imanishi , A. K. Inoue , K. Iwasawa , I. Iwata , A. T. Jaelani , H. -Y. Jian , Y. Kamata , H. Karoji , N. Kashikawa , N. Katayama , S. Kawanomoto , I. Kayo , J. Koda , M. Koike , T. Kojima , Y. Komiyama , A. Konno , S. Koshida , Y. Koyama , H. Kusakabe , A. Leauthaud , C. -H. Lee , L. Lin , Y. -T. Lin , R. H. Lupton , R. Mandelbaum , Y. Matsuoka , E. Medezinski , S. Mineo , S. Miyama , H. Miyatake , S. Miyazaki , R. Momose , A. More , S. More , Y. Moritani , T. J. Moriya , T. Morokuma , S. Mukae , R. Murata , H. Murayama , T. Nagao , F. Nakata , M. Niida , H. Niikura , A. J. Nishizawa , Y. Obuchi , M. Oguri , Y. Oishi , N. Okabe , Y. Okura , Y. Ono , M. Onodera , M. Onoue , K. Osato , M. Ouchi , P. A. Price , T. -S. Pyo , M. Sako , S. Okamoto , M. Sawicki , T. Shibuya , K. Shimasaku , A. Shimono , M. Shirasaki , J. D. Silverman , M. Simet , J. Speagle , D. N. Spergel , M. A. Strauss , Y. Sugahara , N. Sugiyama , Y. Suto , S. H. Suyu , N. Suzuki , P. J. Tait , T. Takata , M. Takada , N. Tamura , M. M. Tanaka , M. Tanaka , M. Tanaka , Y. Tanaka , T. Terai , Y. Terashima , Y. Toba , J. Toshikawa , E. L. Turner , T. Uchida , H. Uchiyama , K. Umetsu , F. Uraguchi , Y. Urata , T. Usuda , Y. Utsumi , S. -Y. Wang , W. -H. Wang , K. C. Wong , K. Yabe , Y. Yamada , H. Yamanoi , N. Yasuda , S. Yeh , A. Yonehara , S. Yuma

Optical multiplexing is a key technique that enhances the capacity of optical systems by independently modulating various optical parameters to carry distinct information. Among these parameters, wavelength, polarization, and angle are the…

光学 · 物理学 2024-08-20 Rui Wei , Hongsheng Shi , Boyou Wang , Baojun Li , Yanjun Bao

The PFS is a multi-object spectrograph fed by 2394 fibers at the prime focus of Subaru telescope. Since the F/# at the prime focus is too fast for the spectrograph, we designed a small concave-plano negative lens to be attached to the tip…

Recent advances in astronomical observations have ushered in an era of remarkable discoveries. We now probe the Universe through multi-messenger signals, image the sky with unprecedented depth and resolution, and investigate individual…

天体物理仪器与方法 · 物理学 2026-05-12 Zheng Cai , Song Huang , Yu Liu , Cheng Zhao , Lei Huang

We describe the infrastructure being developed to align and characterize the detectors for the Subaru Measurement of Images and Redshifts (SuMIRe) Prime Focus Spectrograph (PFS). PFS will employ four three-channel spectrographs with an…

天体物理仪器与方法 · 物理学 2015-06-22 Murdock Hart , Robert H. Barkhouser , Michael Carr , Mirek Golebiowski , James E. Gunn , Stephen C. Hope , Stephen A. Smee

We are describing a new multi-fibre positioner, MEFOS, that was in general use at the La Silla Observatory, and implemented at the prime focus of the ESO 3.6 m telescope. It is an arm positioner using 29 arms in a one degree field. Each arm…

天体物理学 · 物理学 2009-09-25 P. Felenbok , J. Guérin , A. Fernandez , V. Cayatte , C. Balkowski , R. C. Kraan-Korteweg

Since 2014, MUSE, the Multi-Unit Spectroscopic Explorer, is in operation at the ESO-VLT. It combines a superb spatial sampling with a large wavelength coverage. By design, MUSE is an integral-field instrument, but its field-of-view and…

天体物理仪器与方法 · 物理学 2015-12-23 Andreas Kelz , Sebastian Kamann , Tanya Urrutia , Peter Weilbacher , Lutz Wisotzki , Roland Bacon

FIRST, the Fibered Imager foR a Single Telescope, is a spectro-imager using single-mode fibers for pupil remapping, allowing measurements beyond the telescope diffraction limit. Integrated on the Subaru Coronagraphic Extreme Adaptive Optics…

Metasurfaces offer compact flat lenses (metalenses) for miniaturized imaging systems; however, the utmost miniaturization requires not only metalenses but also a substantial reduction of free space. A Spaceplate is a flat-optics element…

光学 · 物理学 2026-05-12 Imon Kalyan , Raghvendra P. Chaudhary , Nir Shitrit

We have built an 80-mega pixels (10240 X 8192) mosaic CCD camera, called Suprime-Cam, for the wide-field prime focus of the 8.2 m Subaru telescope. Suprime-Cam covers a field of view 34' X 27', a unique facility among the the 8-10 m class…

We propose a concept of multiplexing lobster-eye (MuLE) optics to achieve significant reductions in the number of focal plane imagers in lobster-eye (LE) wide-field X-ray monitors. In the MuLE configuration, an LE mirror is divided into…

We present the updated design of HighSpec, a high-resolution $\mathcal{R} \sim 20,000$ spectrograph designed for the Multi Aperture Spectroscopic Telescope (MAST). HighSpec offers three observing modes centered at the Ca II H&K, Mg b…

In this paper we present the first on-sky results with the fibered aperture masking instrument FIRST. Its principle relies on the combination of spatial filtering and aperture masking using single-mode fibers, a novel technique that is…

We present the science drivers for the Far-Infrared Enhanced Survey Spectrometer (FIRESS), one of two science instrument on the PRobe Infrared Mission for Astrophysics (PRIMA). FIRESS is designed to meet science objectives in the areas of…