相关论文: Centre line intensity of a supersonic helium beam
Free-jet atomic, cluster and molecular sources are typically used to produce beams of low-energy, neutral particles and find application in a wide array of technologies, from neutral atom microscopes to instruments for surface processing.…
We describe the design, characterization and application of a simple, highly collimated and compact atomic/molecular beam source. This source is based on a segmented capillary design, constructed using a syringe needle. Angular width…
A high-intensity supersonic beam source has been a key component in studies of molecular collisions, molecule-surface interaction, chemical reactions, and precision spectroscopy. However, the molecular density available for experiments in a…
A Bayesian model to infer edge electron density profiles is developed for the JET lithium beam emission spectroscopy system, measuring Li I line radiation using 26 channels with ~1 cm spatial resolution and 10~20 ms temporal resolution. The…
We review known and discuss new signatures of high-intensity Compton scattering assuming a scenario where a high-power laser is brought into collision with an electron beam. At high intensities one expects to see a substantial red-shift of…
The study explores machine learning methods for revealing chemical sensitivity in Helium spin-echo spectroscopy, in order to obtain ultra-sensitive surface analytic technique. We model bi-species co-adsorbed systems and demonstrate that by…
Neutral helium atom microscopy is a novel microscopy technique that offers strictly surface-sensitive, non-destructive imaging. Several experiments have been published in recent years where images are obtained by scanning a helium beam spot…
A scanning helium microscope typically utilises a thermal energy helium atom beam, with an energy and wavelength (<100 meV, ~0.05 nm) particularly sensitive to surface structure. An angular detector stage for a scanning helium microscope is…
The sensitivity of future gravitational wave (GW) observatories will be limited by thermal noise in a wide frequency band. To reduce thermal noise, the European GW observatory Einstein GW Telescope (ET) is suggested to use crystalline…
Helium implantation in surfaces is of interest for plasma facing materials and other nuclear applications. Vanadium as both a representative bcc material and a material relevant for fusion applications is implanted using a Helium ion beam…
A novel, to the best of our knowledge, ultralow-temperature luminescence thermometry strategy is proposed, based on a measurement of relative intensities of hyperfine components in the spectra of Ho$^{3+}$ ions doped into a crystal. A…
The study of Stark broadening of neutral helium lines, despite significant advances over recent decades, has not led to updated large grids of helium line profiles relevant to the spectroscopic study of helium-rich stars. While the…
Line intensity mapping (LIM) is a promising approach to study star formation and the interstellar medium (ISM) in galaxies by measuring the aggregate line emission from the entire galaxy population. In this work, we develop a simple yet…
The focused helium ion beam microscope is a versatile imaging and nanofabrication instrument enabling direct-write lithography with sub-10-nm resolution. Subsurface damage and swelling of substrates due to helium ion implantation is…
In this paper, we examine a new updated solar model taking advantage of recent reexamination of the nuclear reactions rates and of the microscopic diffusion of helium and heavy elements. Our best model fits the helioseismic data reasonably…
We have combined the detailed He I recombination model of Smits with the collisional transitions of Sawey & Berrington in order to produce new accurate helium emissivities that include the effects of collisional excitation from both the 2…
Line intensity mapping using atomic hydrogen (HI) has the potential to efficiently map large volumes of the universe if the signal can be successfully separated from overwhelmingly bright radio foreground emission. This motivates…
In this paper we discuss two approximate methods previously suggested for modeling hyperfine spectral line emission for molecules whose collisional transitions rates between hyperfine levels are unknown. Hyperfine structure is seen in the…
Aims: Hydrogen and helium line spectra are crucial diagnostic features for the quantitative analysis of OB stars. We compute synthetic spectra based on a hybrid non-LTE approach in order to test the ability of these models to reproduce…
Sub-nanometer and nanometer-sized tips provide high coherence electron sources. Conventionally, the effective source size is estimated from the extent of the experimental biprism interference pattern created on the detector by applying the…