相关论文: Energy Loss Due to Defect Formation from $^{206}$P…
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction,…
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed…
The threshold displacement energy in solid state detector materials varies from several eV to ~100 eV. If a stable or long lived defect is created as a result of a nuclear recoil event, some part of the recoil energy is stored in the…
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for…
Germanium is the detector material of choice in many rare-event searches looking for low-energy nuclear recoils induced by dark matter particles or neutrinos. We perform a systematic exploration of its quenching factor for sub-keV nuclear…
The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run…
This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the…
We report an absolute energy response function to electronic and nuclear recoils for germanium and liquid xenon detectors. As a result, we show that the detection energy threshold of nuclear recoils for a dual-phase xenon detector can be a…
The discrepancies in claims of experimental evidence in the search for weakly interacting massive particle (WIMP) dark matter necessitate a model for ionization efficiency (the quenching factor) at energies below 10 keV. We have carefully…
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with…
The Edelweiss collaboration performs light Dark Matter (DM) particles searches with germanium bolometer collecting charge and phonon signals. Thanks to the Neganov-Trofimov-Luke (NTL) effect, a RMS resolution of 4.46 electron-hole pairs was…
We report a new result of the temperature-dependent average energy expended per electron-hole (e-h) pair, $\varepsilon$, for germanium detectors. Applying energy partition mechanism in ionization for a given energy deposition, the Fano…
We propose to use the defect creation energy loss in commonly used high energy physics solid state detectors as a tool to statistically identify dark matter signal from background. We simulate the energy loss in the process of defect…
The creation of point defects in the crystal lattices of various semiconductors by subthreshold events has been reported on by a number of groups. These observations have been made in great detail using sensitive electrical techniques but…
The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to…
In light of recent results from low-threshold dark matter detectors, we revisit the possibility of a common dark matter origin for multiple excesses across numerous direct detection experiments, with a focus on the excess rates in…
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal…
An excess of events of unknown origin at low energies below 1 keV has been observed in multiple low-threshold dark matter detectors. Depending on the target material, nuclear recoil events at these energies may cause lattice defects, in…
We report the first results from a search for weakly interacting massive particles (WIMPs) in the Cryogenic Dark Matter Search (CDMS) experiment at the Soudan Underground Laboratory. Four Ge and two Si detectors were operated for 52.6 live…