中文
相关论文

相关论文: Time calibration of the J-PET detector

200 篇论文

A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper…

In this paper, we introduce a laboratory prototype of a solar energetic particle (SEP) detector which will operate along with other space-based instruments to give us more insight into the SEP physics. The instrument is designed to detect…

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any…

Discrimination of fast neutrons, thermal neutrons, and $\gamma$ rays in mixed radiation fields is important for radiation monitoring, reactor-related measurements, and background suppression in nuclear experiments. In this work, we…

仪器与探测器 · 物理学 2026-04-30 Yuhang Liu , Fengpeng An , Guang Luo , Wei Wang , Xuesong Zhang , Dixiao Lu , Xiaohao Yin

Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon…

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

仪器与探测器 · 物理学 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is…

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…

仪器与探测器 · 物理学 2015-06-18 M. De Gerone , F. Gatti , W. Ootani , Y. Uchiyama , M. Nishimura , S. Shirabe , P. W. Cattaneo , M. Rossella

A novel plastic scintillator, referred to as J-PET scintillator, has been developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole…

仪器与探测器 · 物理学 2017-10-24 Anna Wieczorek

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of…

仪器与探测器 · 物理学 2012-02-03 C. Lang , D. Habs , P. G. Thirolf , A. Zoglauer

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and…

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma…

医学物理 · 物理学 2013-10-15 P. Moskal , P. Salabura , M. Silarski , J. Smyrski , J. Zdebik , M. Zieliński

A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…

仪器与探测器 · 物理学 2024-08-19 N. Karpushkin , D. Finogeev , F. Guber , D. Lyapin , A. Makhnev , S. Morozov , D. Serebryakov

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

The TRIDENT (Tropical Deep-sea Neutrino Telescope) experiment is a next-generation underwater neutrino observatory planned for deployment in the West Pacific Ocean, designed to detect astrophysical neutrinos through Cherenkov radiation. The…

仪器与探测器 · 物理学 2025-11-20 Guangping Zhang , Yong Yang , Donglian Xu

Plastic scintillator detectors with three-dimensional granularity and sub-nanosecond time resolution offer simultaneous particle tracking, identification, and calorimetry. However, scaling to larger volumes and finer segmentation poses…

仪器与探测器 · 物理学 2024-12-31 Umut Kose

The exponential growth of photonic quantum technologies is driving the demand of tools for measuring the quality of their information carriers. One of the most prominent is Stimulated Emission Tomography (SET), which uses classical coherent…

量子物理 · 物理学 2020-04-22 Massimo Borghi

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

仪器与探测器 · 物理学 2023-03-07 Mayank Goswami , Kajal Kumari