中文
相关论文

相关论文: Time calibration of the J-PET detector

200 篇论文

Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic…

Positron emission tomography (PET) is a medical imaging method based on the measurement of concentrations of positron-emitting radionuclides in a living body. In the PET imaging system, glucose is labeled with a positron-emitting…

信号处理 · 电气工程与系统科学 2022-09-27 Mehmet Akif Ozdemir , Ali Tangel

We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer…

Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…

机器人学 · 计算机科学 2023-12-07 Junxiang Wang , Ti Wu , Iulian I. Iordachita , Peter Kazanzides

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of…

Positronium Imaging requires two classes of events: double-coincidences originated from pair of back-to-back annihilation photons and triple-coincidences comprised with two annihilation photons and one additional prompt photon. The standard…

医学物理 · 物理学 2025-08-11 Lech Raczynski , Wojciech Krzemien , Konrad Klimaszewski

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

仪器与探测器 · 物理学 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti

Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…

仪器与探测器 · 物理学 2020-08-03 Jeremy M. C. Brown

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…

仪器与探测器 · 物理学 2015-06-11 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…

PETALO (Positron Emission TOF Apparatus with Liquid xenOn) is a project that uses liquid xenon as a scintillation medium, silicon photomultipliers as a readout and fast electronics to provide a significant improvement in PET-TOF technology.…

仪器与探测器 · 物理学 2023-11-17 Nerea Salor Iguiñiz

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

仪器与探测器 · 物理学 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40…

Transforming the resistive plate chambers from charged-particle into gamma-quanta detectors opens the way towards their application as a basic element of a hybrid imaging system, which combines positron emission tomography (PET) with…

The reliable detection of neutrons in a harsh gamma-ray environment is an important aspect of establishing non-destructive methods for the characterization of spent nuclear fuel. In this study, we present results from extended in-situ…

仪器与探测器 · 物理学 2021-10-22 Hanno Perrey , Linus Ros , Mikael Elfman , Ulrika Bäckström , Per Kristiansson , Anders Sjöland

The integration of positron emission tomography (PET) and magnetic resonance imaging (MRI) has been an ongoing research topic for the last 20 years. This paper gives an overview of the different developments and the technical problems…

医学物理 · 物理学 2015-10-19 Stefaan Vandenberghe , Paul Marsden

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

医学物理 · 物理学 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical…

仪器与探测器 · 物理学 2009-08-03 P. -E. Vert , J. Lecoq , G. Montarou , N. Pauna , B. Joly , M. Boutemeur , H. Mathez , R. Gaglione , P. Le Dû