相关论文: Commissioning of te China-ADS injector-I testing f…
We use point contact spectroscopy (PCS) to probe the superconducting properties of electron doped $\rm{Ba(Fe_{1-x}Co_x)_2As_2}$ ($\rm{x = 0.05, 0.055, 0.07, 0.08}$) and hole doped $\rm{Ba_{0.8}K_{0.2}Fe_2As_2}$. PCS directly probes the low…
The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…
The Beijing Electron Collider is being upgraded (BEPCII) to a two-ring collider with a design luminosity of $1 \times 10^{33}$cm$^{-2}$ s$^{-1}$ at a center-of-mass energy of 3.89 GeV. It will operate between 2 and 4.2 GeV in the center of…
The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the…
The Heating Neutral Beam Injectors (HNBs) for ITER will have to deliver 16.7 MW beams of H/D particles at 1 MeV energy. The beams will be produced from H-/D- ions, generated by a radiofrequency plasma source coupled to an ion acceleration…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
The design of the Linac Coherent Light Source assumes that a low-emittance, 1-nC, 10-ps beam will be available for injection into the 15-GeV linac. The proposed rf photocathode injector that will provide a 150-MeV beam with rms normalized…
The CLIC Test Facility (CTF3) is an intermediate step to demonstrate the technical feasibility of the key concepts of the new RF power source for CLIC. CTF3 will use electron beams with an energy range adjustable from 170 MeV (3.5 A) to 380…
5-cell elliptical cavities are chosen for the main linac of China Accelerator Driven sub-critical System in the medium energy section. Each cavity is driven by one fundamental power coupler delivering RF power up to 150 kW. A single window,…
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number…
The Australia Telescope Compact Array (ATCA) has been used to image class I methanol masers at 9.9, 25 (a series from J=2 to J=9), 84, 95 and 104 GHz located in the vicinity of IRAS 16547-4247 (G343.12-0.06), a luminous young stellar object…
We present the technical and engineering design of a medium energy (10 MeV) and high average power (1 MW) electron beam accelerator intended for irradiation treatment of high volume industrial and municipal wastewater. The accelerator uses…
Intelligent reflecting surfaces (IRSs) have attracted considerable attention because of their ability to dynamically control electromagnetic wave propagation. While most existing IRSs have been developed for low-power communication and…
An essential design requirement of the ALPS-II experiment is the efficient detection of single photons with a very low instrumental background of 10 {\mu}Hz. In 2011 the ALPS collaboration started to set up a TES detector (Transition-Edge…
The Advanced Light Source was commissioned 10 years ago using the newly constructed control system. Further experience with the control system was reported in 1993. In this publication, we report on recent experience with the operation and…
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over…
In order to update the beam power from 100 kW to 250 kW in China spallation neutron source (CSNS) Phase II, one of the important measures is to replace the 80 meters long beam transport line between the present 80 MeV linac injector and the…
The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles…
MITICA (Megavolt ITER Injector & Concept Advancement), the full scale prototype of ITER Heating Neutral Beam, is under realization at the Neutral Beam Test Facility (Padova, Italy). It is designed to deliver 16.5 MW to ITER plasma, obtained…