相关论文: Gilbert damping of magnetostatic modes in a yttriu…
We investigate the temperature dependent microwave absorption spectrum of an yttrium iron garnet sphere as a function of temperature (5 K to 300 K) and frequency (3 GHz to 43.5 GHz). At temperatures above 100 K, the magnetic resonance…
We report strong damping enhancement in a 200 nm thick yttrium iron garnet (YIG) film due to spin inhomogeneity at the interface. The growth-induced thin interfacial gadolinium iron garnet (GdIG) layer antiferromagnetically (AFM) exchange…
The linewidth of antiferromagnetic resonance (AFMR) is found to be significantly broader than that of ferromagnetic resonance (FMR), even when the intrinsic Gilbert damping parameter is the same for both systems. We investigate the origin…
We demonstrate the dispersive measurement of ferromagnetic resonance in a yttrium iron garnet sphere embedded within a microwave cavity. The reduction in the longitudinal magnetization at resonance is measured as a frequency shift in the…
We investigated the spin-wave propagation in a micro-structured yttrium iron garnet waveguide of $40$ nm thickness. Utilizing spatially-resolved Brillouin light scattering microscopy, an exponential decay of the spin-wave amplitude of…
In-situ, device level measurement of thermal mag-noise spectral linewidths in 60nm diameter CPP-GMR spin-valve stacks of IrMn/ref/Cu/free, with reference and free layer of similar CoFe/CoFeGe alloy, are used to simultaneously determine the…
We present a systematic phenomenological description of Gilbert damping in two-sublattice magnets. Our theory covers the full range of materials from ferro- via ferri- to antiferromagnets. Following a Rayleigh dissipation functional…
An improved method for characterizing the magnetic anisotropy of films with cubic symmetry is described and is applied to an yttrium iron garnet (111) film. Analysis of the FMR spectra performed both in-plane and out-of-plane from 0.7 to 8…
We present a comprehensive investigation of propagating spin waves in nanometer-thick yttrium iron garnet (YIG) films. We use broadband spin-wave spectroscopy with integrated coplanar waveguides (CPWs) and microstrip antennas on top of…
We report on broadband ferromagnetic resonance linewidth measurements performed on epitaxial Heusler thin films. A large and anisotropic two-magnon scattering linewidth broadening is observed for measurements with the magnetization lying in…
Chiral magnets with topologically nontrivial spin order such as Skyrmions have generated enormous interest in both fundamental and applied sciences. We report broadband microwave spectroscopy performed on the insulating chiral ferrimagnet…
We report measurements of the frequency and temperature dependence of ferromagnetic resonance (FMR) for a 15-nm-thick yttrium iron garnet (YIG) film grown by off-axis sputtering. Although the FMR linewidth is narrow at room temperature…
Quantum magnonics aims to exploit the quantum mechanical properties of magnons for nanoscale quantum information technologies. Ferrimagnetic yttrium iron garnet (YIG), which offers the longest magnon lifetimes, is a key material typically…
We study the spin dynamics of a ferromagnetic insulator on which graphene is placed. We show that the Gilbert damping is enhanced by the proximity exchange coupling at the interface. The modulation of the Gilbert damping constant is…
Using broadband ferromagnetic resonance, we measure the damping parameter of [Co(5 \r{A})/Pt(3 \r{A})]${\times 6}$ multilayers whose growth was optimized to maximize the perpendicular anisotropy. Structural characterizations indicate abrupt…
We present a ferromagnetic resonance (FMR) study of the effect of Helium ion irradiation on the magnetic anisotropy, the linewidth and the Gilbert damping of a Co/Ni multilayer coupled to Co/Pd bilayers. The perpendicular magnetic…
We investigated the effect of an external magnetic field on the diffusive spin transport by magnons in the magnetic insulator yttrium iron garnet (YIG), using a non-local magnon transport measurement geometry. We observed a decrease in…
A dipper probe for broadband Ferromagnetic Resonance (FMR) operating from 4.2 K to room temperature is described. The apparatus is based on a 2-port transmitted microwave signal measurement with a grounded coplanar waveguide. The waveguide…
Using the in-in formalism, we generalize the recently constructed magnetoelastic EFT arXiv:2112.13873 [hep-th] to describe the damping dynamics of ferromagnetic systems at long wavelengths. We find that the standard Gilbert damping term…
We investigate the spin dynamics including Gilbert damping in the ferromagnetic nanowire arrays. We have measured the ferromagnetic resonance of ferromagnetic nanowire arrays using vector-network analyzer ferromagnetic resonance (VNA-FMR)…