Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC…

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on…

Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based…

天体物理仪器与方法 · 物理学 2016-11-17 J. van der Kuur , L. G. Gottardi , H. Akamatsu , B. J. van Leeuwen , R. den Hartog , D. Haas , M. Kiviranta , B. J. Jackson

We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in the early 2030s.5$\times$5 mixed arrays with TiAu…

The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028.…

We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different…

We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…

We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass…

The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic…

The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It…

SRON (Netherlands Institute for Space Research) is developing the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board…

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution…

天体物理仪器与方法 · 物理学 2018-07-18 Didier Barret , Thien Lam Trong , Jan-Willem den Herder , Luigi Piro , Massimo Cappi , Juhani Huovelin , Richard Kelley , J. Miguel Mas-Hesse , Kazuhisa Mitsuda , Stéphane Paltani , Gregor Rauw , Agata Rozanska , Joern Wilms , Simon Bandler , Marco Barbera , Xavier Barcons , Enrico Bozzo , Maria Teresa Ceballos , Ivan Charles , Elisa Costantini , Anne Decourchelle , Roland den Hartog , Lionel Duband , Jean-Marc Duval , Fabrizio Fiore , Flavio Gatti , Andrea Goldwurm , Brian Jackson , Peter Jonker , Caroline Kilbourne , Claudio Macculi , Mariano Mendez , Silvano Molendi , Piotr Orleanski , François Pajot , Etienne Pointecouteau , Frederick Porter , Gabriel W. Pratt , Damien Prêle , Laurent Ravera , Kosuke Sato , Joop Schaye , Keisuke Shinozaki , Tanguy Thibert , Luca Valenziano , Veronique Valette , Jacco Vink , Natalie Webb , Michael Wise , Noriko Yamasaki , Françoise Delcelier-Douchin , Jean-Michel Mesnager , Bernard Pontet , Alice Pradines , Graziella Branduardi-Raymont , Esra Bulbul , Mauro Dadina , Stefano Ettori , Alexis Finoguenov , Yasushi Fukazawa , Agnieszka Janiuk , Jelle Kaastra , Pasquale Mazzotta , Jon Miller , Giovanni Miniutti , Yaël Nazé , Fabrizio Nicastro , Salvatore Sciortino , Aurora Simionescu , Jose Miguel Torrejon , Benoît Frezouls , Hervé Geoffray , Philippe Peille , Corinne Aicardi , Jérôme André , Antoine Clénet , Christophe Daniel , Christophe Etcheverry , Emilie Gloaguen , Gilles Hervet , Antoine Jolly , Aurélien Ledot , Irwin Maussang , Alexis Paillet , Roseline Schmisser , Bruno Vella , Jean-Charles Damery , Kevin Boyce , Michael DiPirro , Simone Lotti , Denis Schwander , Stephen Smith , Bert-Joost van Leeuwen , Henk van Weers , Nicolas Clerc , Beatriz Cobo , Thomas Dauser , Jelle de Plaa , Christian Kirsch , Edoardo Cucchetti , Megan Eckart , Philippe Ferrando , Lorenzo Natalucci

We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a…

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics, science goals require very high resolution…

仪器与探测器 · 物理学 2021-02-19 E. Taralli , C. Pobes , P. Khosropanah , L. Fabrega , A. Camon , L. Gottardi , K. Nagayoshi , M. Ridder , M. Bruijn , J. R. Gao

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is AC voltage biased at a well defined frequencies (between…

In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of…

At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the…

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…