中文
相关论文

相关论文: Minimum Sparsity of Unobservable Power Network Att…

200 篇论文

Recent work on complex networks compared the topological and electrical structures of the power grid, taking into account the underlying physical laws that govern the electrical connectivity between various components in the network. A…

系统与控制 · 计算机科学 2013-09-06 K. G. Nagananda

Prior research has demonstrated that global positioning system (GPS) spoofing attacks on phasor measurement units (PMUs) can cripple power system operation. This paper provides an experimental evidence of the feasibility of such an attack…

密码学与安全 · 计算机科学 2021-10-08 Fakhri Saadedeen , Anamitra Pal

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…

系统与控制 · 电气工程与系统科学 2020-09-08 Xiaozhou Yang , Nan Chen , Chao Zhai

This paper proposes a procedure to solve combinatorial power network design problems such as phasor measurement unit (PMU) placement and protection assignment against cyber-physical attacks. The proposed approach tackles the design problems…

最优化与控制 · 数学 2016-02-19 Kin Cheong Sou

The widespread use of publicly available datasets for training machine learning models raises significant concerns about data misuse. Availability attacks have emerged as a means for data owners to safeguard their data by designing…

机器学习 · 计算机科学 2025-03-11 Yu Zhe , Jun Sakuma

Timely recognition of voltage instability is crucial to allow for effective control and protection interventions. Phasor measurements units (PMUs) can be utilized to provide high sampling rate time-synchronized voltage and current phasors…

系统与控制 · 计算机科学 2013-08-05 R. Leelaruji , L. Vanfretti , J. O. Gjerde , S. Lovlund

Physical consequences to power systems of false data injection cyber-attacks are considered. Prior work has shown that the worst-case consequences of such an attack can be determined using a bi-level optimization problem, wherein an attack…

系统与控制 · 计算机科学 2016-05-24 Zhigang Chu , Jiazi Zhang , Oliver Kosut , Lalitha Sankar

In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…

最优化与控制 · 数学 2014-10-08 Junjian Qi , Kai Sun , Wei Kang

This paper addresses problems on the robust structural design of complex networks. More precisely, we address the problem of deploying the minimum number of dedicated sensors, i.e., those measuring a single state variable, that ensure the…

最优化与控制 · 数学 2016-06-13 Xiaofei Liu , Sergio Pequito , Soummya Kar , Bruno Sinopoli , A. Pedro Aguiar

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the…

系统与控制 · 电气工程与系统科学 2020-04-16 Alexey Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer , M. Nicolai L. Lorenz-Meyer

Phasor Measurement Units (PMUs) are measurement devices long used in transmission systems and today even more essential for a proper monitoring of distribution grids. The expected massive penetration of distributed energy resources (DERs)…

系统与控制 · 电气工程与系统科学 2020-03-03 Carlo Guarnieri Calo\' Carducci , Gianluca Lipari , Nicola Giaquinto , Ferdinanda Ponci , Antonello Monti

Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a…

系统与控制 · 电气工程与系统科学 2021-05-06 Lorena Palmero , Ugur Saritac , Ali Dehghan Chaharabi

The GPS is vulnerable to GPS spoofing attack (GSA), which leads to disorder in time and position results of the GPS receiver. In power grids, phasor measurement units (PMUs) use GPS to build time-tagged measurements, so they are susceptible…

系统与控制 · 电气工程与系统科学 2023-09-12 Mohammad Sabouri , Sara Siamak , Maryam Dehghani , Mohsen Mohammadi , Mohammad Hassan Asemani

In this paper, a novel graph-theoretic framework is proposed to generalize the analysis of a broad set of security attacks, including observability and data injection attacks, that target the state estimator of a smart grid. First, the…

系统与控制 · 计算机科学 2020-02-05 Anibal Sanjab , Walid Saad , Tamer Başar

Recent research has shown that the security of power grids can be seriously threatened by botnet-type cyber attacks that target a large number of high-wattage smart electrical appliances owned by end-users. Accurate detection and…

密码学与安全 · 计算机科学 2022-09-08 Hamidreza Jahangir , Subhash Lakshminarayana , Carsten Maple

In this paper we study the question of how to reconstruct the state of a power system using Phasor Measurement Units (PMUs). In our previous research we proved that this question has an affirmative answer imposing some rather strict…

系统与控制 · 电气工程与系统科学 2024-10-08 Alexey Bobtsov , Romeo Ortega , Nicolai Lorenz-Meyer , Johannes Schiffer

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it…

系统与控制 · 电气工程与系统科学 2020-10-16 Hamed Haggi , Wei Sun , Junjian Qi

Dynamic state and parameter estimation methods for dynamic security assessment in power systems are becoming increasingly important for system operators. Usually, the data used for this type of applications stems from phasor measurement…

系统与控制 · 电气工程与系统科学 2022-09-01 Nicolai Lorenz-Meyer , René Suchantke , Johannes Schiffer

A tri-objective optimal Micro Phasor Measurement Units ({\mu}-PMUs) Placement method is presented, with a focus on minimizing the following three parameters: i) the total number of {\mu}-PMU channels, (ii) the maximum state estimation…

系统与控制 · 电气工程与系统科学 2023-09-04 Arya Abdolahi , Navid Taghizadegan Kalantari

Real-time transmission line outage detection is difficult because of partial phasor measurement unit (PMU) deployment and varying outage signal strength. Existing detection approaches focus on monitoring PMU-measured nodal algebraic states,…

系统与控制 · 电气工程与系统科学 2021-10-28 Xiaozhou Yang , Nan Chen , Chao Zhai