中文
相关论文

相关论文: Photon counting spectroscopic CT with dynamic beam…

200 篇论文

Cone beam computed tomography (CBCT) images can be used for dose calculation in adaptive radiation therapy (ART). The main challenges are the large artefacts and inaccurate Hounsfield unit (HU) values. Currently, deformed planning CT images…

医学物理 · 物理学 2019-09-04 Xiao Liang , Liyuan Chen , Dan Nguyen , Zhiguo Zhou , Xuejun Gu , Ming Yang , Jing Wang , Steve Jiang

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral…

Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy…

医学物理 · 物理学 2020-03-03 Mats Persson , Adam Wang , Norbert J. Pelc

Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used…

Computer-Assisted Interventions enable clinicians to perform precise, minimally invasive procedures, often relying on advanced imaging methods. Cone-beam computed tomography (CBCT) can be used to facilitate computer-assisted interventions,…

图像与视频处理 · 电气工程与系统科学 2024-12-04 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

This study aimed to propose a denoising method for dynamic contrast-enhanced computed tomography (DCE-CT) perfusion studies using a three-dimensional deep image prior (DIP), and to investigate its usefulness in comparison with total…

医学物理 · 物理学 2023-04-04 Kenya Murase

We demonstrate that in situ coherent diffractive imaging (CDI), which harnesses the coherent interference between a strong and a weak beam illuminating a static and dynamic structure, can be a very dose-efficient imaging method. At low…

光学 · 物理学 2024-05-07 Xingyuan Lu , Minh Pham , Elisa Negrini , Damek Davis , Stanley J. Osher , Jianwei Miao

Background: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm…

医学物理 · 物理学 2026-02-04 Namhoon Kim , Ashwin Pananjady , Amir Pourmorteza , Sara Fridovich-Keil

Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body,…

Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal…

图像与视频处理 · 电气工程与系统科学 2023-09-26 Obaidullah Rahman , Ken D. Sauer , Charles A. Bouman , Roman Melnyk , Brian Nett

Diffusion models have significant impact on wide range of generative tasks, especially on image inpainting and restoration. Although the improvements on aiming for decreasing number of function evaluations (NFE), the iterative results are…

图像与视频处理 · 电气工程与系统科学 2024-11-20 Mahmut S. Gokmen , Jie Zhang , Ge Wang , Jin Chen , Cody Bumgardner

The dark photon is a new hypothetical gauge boson arising in extensions of the Standard Model, and constitutes a compelling dark matter candidate. As dark photon dark matter (DPDM), it can interact with electromagnetic fields via kinetic…

高能天体物理现象 · 物理学 2026-02-26 Júlia G. Mamprim , Aion Viana , Vitor de Souza

Inferior soft-tissue contrast resolution is a major limitation of current CT scanners. The aim of the study is to improve the contrast resolution of CT scanners using dual-energy acquisition. Based on dual-energy material decomposition, the…

医学物理 · 物理学 2016-11-15 Wei Zhao , Lu Wan , Bo Zhang , Qiude Zhang , Tianye Niu

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in…

图像与视频处理 · 电气工程与系统科学 2026-03-30 Naruki Murahashi , Mitsuhiro Nakamura , Megumi Nakao

This paper proposes a novel and fast self-supervised solution for sparse-view CBCT reconstruction (Cone Beam Computed Tomography) that requires no external training data. Specifically, the desired attenuation coefficients are represented as…

图像与视频处理 · 电气工程与系统科学 2022-09-30 Ruyi Zha , Yanhao Zhang , Hongdong Li

In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises the signal-to-noise…

图像与视频处理 · 电气工程与系统科学 2024-07-02 Haoyu Zhao , Yuliang Gu , Zhou Zhao , Bo Du , Yongchao Xu , Rui Yu

Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views…

医学物理 · 物理学 2016-08-01 Lei Li , Ailong Cai , Linyuan Wang , Bin Yan , Hanming Zhang , Zhizhong Zheng , Wenkun Zhang , Wanli Lu , Guoen Hu

Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…

医学物理 · 物理学 2025-02-04 S. Gros , J. Bian , J. Jackson , M. Delafuente , H. Kang , W. Small , M. Mahesh

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is, therefore, challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable…

医学物理 · 物理学 2019-11-01 Wei Zhao , Tianling Lv , Peng Gao , Liyue Shen , Xianjin Dai , Kai Cheng , Mengyu Jia , Yang Chen , Lei Xing

Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound (US) imaging and the contrast of pure optical imaging. For linear-array PAI, a beamformer has to be used as the…

医学物理 · 物理学 2018-02-15 Moein Mozaffarzadeh , Yan Yan , Mohammad Mehrmohammadi , Bahador Makkiabadi