相关论文: Development of a two-dimensional imaging GEM detec…
We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers: CuO or CrO. These detectors can operate stably at gains close to 10E5 and they are very robust. We discovered that the…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
We report the status of R&D on large triple-GEM detectors for a forward tracker (FT) in an experiment at a future Electron Ion Collider (EIC) that will improve our understanding of QCD. We have designed a detector prototype specifically…
Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…
A 1-meter-long trapezoidal Triple-GEM detector with wide readout strips was tested in hadron beams at the Fermilab Test Beam Facility in October 2013. The readout strips have a special zigzag geometry and run along the radial direction with…
Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…
We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…
The advancement of Micro Pattern Gaseous Detector technology offers us different kinds of detectors with good spatial resolution and high rate capability and the Gas Electron Multiplier (GEM) detector is one of them. Typically GEM is made…
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The…
The two high-angle Time Projection Chambers of the T2K experiment are equipped with a new readout system based on resistive Micromegas detector technology, and utilize custom-made electronics based on AFTER chips for signal processing. This…
We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…
Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…
A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant…
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas…
The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for…
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the…