中文
相关论文

相关论文: Optical designs for the Maunakea Spectroscopic Exp…

200 篇论文

We report the results of interferometric observations of Centaurus A with the MID-infrared Interferometer (MIDI) at ESO's VLTI telescope array. The interferometric measurements are spectrally resolved (R = 30) in the wavelength range 8 to…

The novel Gaia Multi Peak (GMP) technique has proven to be able to successfully select dual and lensed AGN candidates at sub-arcsec separations. Both populations are important because dual AGN represent one of the central, still largely…

As an in-house instrument developmental activity at ARIES, the 4Kx4K CCD Imager is designed and developed as a first-light instrument for the axial port of the 3.6m DOT. The f/9 beam of the telescope having a plate-scale of ~ 6.4 arc-sec/mm…

天体物理仪器与方法 · 物理学 2017-11-16 S. B. Pandey , R. K. S. Yadav , Nandish Nanjappa , Shobhit Yadav , B. Krishna Reddey , Sanjeet Sahu , R. Srinivasan

We present details of the design for the CCD readout electronics for the Subaru Telescope Prime Focus Spectrograph (PFS). The spectrograph is comprised of four identical spectrograph modules, each collecting roughly 600 spectra. The…

天体物理仪器与方法 · 物理学 2015-06-22 Stephen C. Hope , James E. Gunn , Craig P. Loomis , Roger E. Fitzgerald , Grant O. Peacock

The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees…

Photoacoustic microscopy (PAM) is a promising imaging modality because it is able to reveal optical absorption contrast in high resolution on the order of a micrometer. It can be applied in an endoscopic approach by implementing PAM into a…

医学物理 · 物理学 2019-11-22 Zhendong Guo , Zhanhong Ye , Weihao Shao , Lili Jing , Sung-Liang Chen

We present the design of a diffraction limited, long working distance monochromatic objective lens for efficient light collection. Consisting of four spherical lenses, it has a numerical aperture of 0.29, an effective focal length of 36 mm…

光学 · 物理学 2009-11-07 Wolfgang Alt

The 21-cm absorption feature reported by the EDGES collaboration is several times stronger than that predicted by traditional astrophysical models. If genuine, a deeper absorption may lead to stronger fluctuations on the 21-cm signal on…

A critical challenge for the integration of the optoelectronics is that photodetectors have relatively poor sensitivities at the nanometer scale. It is generally believed that a large electrodes spacing in photodetectors is required to…

介观与纳米尺度物理 · 物理学 2015-01-27 Yufei Cao , Kaiming Cai , Pingan Hu , Lixia Zhao , Tengfei Yan , Xinhui Zhang , Xiaoguang Wu , Kaiyou Wang , Houzhi Zheng

Dark Energy studies with type Ia supernovae set very tight constraints on the photometric calibration of the imagers used to detect the supernovae and follow up their flux variations. Among the key challenges is the measurement of the shape…

天体物理仪器与方法 · 物理学 2012-09-03 N. Regnault , E. Barrelet , A. Guyonnet , C. Juramy , P. -F. Rocci , L. Le Guillou , K. Schahmanèche , F. Villa

Compton telescopes based on semiconductor technologies are being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of…

Development of the Silicon photomultiplier Elementary Cell Add-on camera (SiECA) has provided extensive information regarding the use of SiPMs for future cosmic ray detection systems. We present the technical aspects of sensor readout…

天体物理仪器与方法 · 物理学 2019-08-27 W. Painter , A. Haungs , T. Huber , M. Karus , A. Menshikov , M. Oehler , M. Renschler , JEM-EUSO Collaboration

Atmospheric dispersion causes light from celestial objects with different wavelengths to refract at varying angles as it passes through Earth's atmosphere. This effect results in an elongated image at the focal plane of a telescope and…

We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of…

We present details of characterization and imaging performance of the Cananea Near-infrared camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico. CANICA has a HAWAII…

天体物理仪器与方法 · 物理学 2018-04-04 R. Devaraj , Y. D. Mayya , L. Carrasco , A. Luna

WST - Widefield Spectroscopic Telescope: We summarise the design challenges of instrumentation for a proposed 12m class Telescope that aims to provide a large (>2.5 square degree) field of view and enable simultaneous Multi-object (> 20,000…

The sodium laser guide star adaptive optics system ALFA has been constructed at the Calar Alto 3.5-m telescope. Following the first detection of the laser beacon on the wavefront sensor in 1997 the system is now being optimized for best…

天体物理学 · 物理学 2015-06-24 R. I. Davies , W. Hackenberg , T. Ott , A. Eckart , H. -C. Holstenberg , S. Rabien , A. Quirrenbach , M. Kasper

Since its beginnings, diffraction-limited ground-based adaptive optics (AO) imaging has been limited to wavelengths in the near IR ({\lambda} > 1 micron) and longer. Visible AO ({\lambda} < 1 micron) has proven to be difficult because…

天体物理仪器与方法 · 物理学 2010-08-03 Derek Kopon , Jared R. Males , Laird M. Close , Victor Gasho

The FASER experiment at the LHC aims to detect new, long-lived fundamental particles. A tungsten-silicon (W-Si) preshower detector is being developed to enhance the experiment's ability to distinguish between closely spaced photon pairs…

仪器与探测器 · 物理学 2024-10-01 Rafaella Eleni Kotitsa

The epitaxial growth of two-dimensional (2D) $\beta-In_2Se_3$ material was obtained over 2-inches c-sapphire wafers using molecular beam epitaxy (MBE). Excellent quality of thick (90 nm) and very thin films, down to two quintuple layers (2…

‹ 上一页 1 8 9 10 下一页 ›