中文
相关论文

相关论文: Measurement of the dead layer thickness in a p-typ…

200 篇论文

The ability of background discrimination using pulse shape discrimination (PSD) in broad-energy germanium (BEGe) detectors makes them as competitive candidates for neutrinoless double beta decay (0{\nu}\b{eta}\b{eta}) experiments. The…

仪器与探测器 · 物理学 2016-06-28 Zhi Zeng , Yu-Hao Mi , Ming Zeng , Hao Ma , Qian Yue , Jian-Ping Cheng , Jun-Li Li , Rui Qiu , Hui Zhang

The China Dark Matter Experiment (CDEX) aims at direct searches of light Weakly Interacting Massive Particles (WIMPs) at the China Jinping Underground Laboratory (CJPL) with an overburden of about 2400m rock. Results from a prototype CDEX-1…

$P$-type high-purity germanium (HPGe) detectors are widely used across many scientific domains, and current data analysis methods have served well in many use cases. However, applications like low-background experiments that search for rare…

仪器与探测器 · 物理学 2026-03-10 P. Zhang , W. Dai , Q. Zhang , F. Hagemann , O. Schulz , C. Alvarez-Garcia , L. Yang , Q. Yue , Z. Zeng , J. Cheng , H. Ma

A model of the Li-diffused inactive layer in P-type high purity germanium detectors is built to describe the transportation of charge carriers and calculate the charge collection efficiency therein. The model is applied to calculate charge…

仪器与探测器 · 物理学 2022-12-29 W. H. Dai , H. Ma , Q. Yue , L. T. Yang , Z. Zeng , J. P. Cheng , J. L. Li

In the rare physics events search, liquid and solid detector plays an important role. Its analysis is based on the detection of excess events over the expected background or on the detection of an annual event rate modulation. Germanium…

仪器与探测器 · 物理学 2021-03-18 Akash Pandey , D. Singh , V. Singh

The China Dark Matter Experiment (CDEX), located at the China Jinping Underground Laboratory (CJPL) whose overburden is about 2400m rock, aims at direct searches of light Weakly Interacting Massive Particles (WIMPs). A single-element…

高能物理 - 实验 · 物理学 2020-03-24 Hao Ma , Ze She , Zhongzhi Liu , Litao Yang , Qian Yue , Zhi Zeng , Tao Xue

The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of…

The p-type point-contact germanium detectors are novel techniques offering kg-scale radiation sensors with sub-keV sensitivities. They have been used for light Dark Matter WIMPs searches and may have potential applications in neutrino…

仪器与探测器 · 物理学 2014-03-14 H. B. Li , the TEXONO Collaboration

This study investigates new technology for enhancing the sensitivity of low-mass dark matter detection by analyzing charge transport in a p-type germanium detector at 5.2 K. To achieve low-threshold detectors, precise calculations of the…

仪器与探测器 · 物理学 2023-07-05 Mathbar Raut , Dongming Mei , Sanjay Bhattarai , Rajendra Panth , Kyler Kooi , Hao Mei , Guojian Wang

The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The…

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an…

The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China JinPing underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in…

P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0vbb) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors…

仪器与探测器 · 物理学 2021-12-09 F. Edzards , L. Hauertmann , I. Abt , C. Gooch , B. Lehnert , X. Liu , S. Mertens , D. C. Radford , O. Schulz , M. Willers

Low-energy background through Compton scattering from the ambient $\gamma$ rays can be contaminated in direct dark matter search experiments. In this paper, we report comparable measurements on low-energy spectra via Compton scattering from…

仪器与探测器 · 物理学 2023-04-26 J. W. Hu , L. T. Yang , Q. Yue , X. P. Geng , H. B. Li , Y. F. Liang , S. T. Lin , S. K. Liu , H. Ma , L. Wang , H. T. Wong , B. T. Zhang

The search for dark matter has been performed mainly for weakly interacting massive particles and massive compact halo objects, and the intermediate mass region has not been investigated experimentally. A method to search dark matter with…

仪器与探测器 · 物理学 2019-01-23 Akio Kawasaki

We report new limits on spin-independent WIMP-nucleon interaction cross-section using 39.5 kg-days of data taken with a p-type point-contact germanium detector of 840 g fiducial mass at the Kuo-Sheng Reactor Neutrino Laboratory. Crucial to…

高能物理 - 实验 · 物理学 2014-05-29 TEXONO Collaboration

A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+…

In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and…

The report describes the research program on the development of ultra-low-energy germanium detectors, with emphasis on WIMP dark matter searches. A threshold of 100 eV is achieved with a 20 g detector array, providing a unique probe to the…

高能物理 - 实验 · 物理学 2008-11-26 H. T. Wong
‹ 上一页 1 2 3 10 下一页 ›