相关论文: Development and tests of a new prototype detector …
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
Time-resolved X-ray Emission/Absorption Spectroscopy (Tr-XES/XAS) is an informative experimental tool sensitive to electronic dynamics in materials, widely exploited in diverse research fields. Typically, Tr-XES/XAS requires X-ray pulses…
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25…
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects…
We present the architectural concept for the Far-Infrared Enhanced Survey Spectrometer (FIRESS) for the Probe Mission for far-IR Astrophysics (PRIMA). FIRESS spans the 24--235 micron range with four R ~ 100 slit-fed grating modules, each…
VOXES is a Von Hamos X-ray spectrometer developed at the INFN National Laboratories of Frascati for high-resolution laboratory X-ray spectroscopy in the 5--20~keV range. It uses curved mosaic crystals and motorized positioning stages to…
Microfluidic devices are increasingly used in synchrotron-based experiments to deliver and probe liquid samples, offering advantages such as minimal sample consumption and reduced radiation damage. Despite their growing use, few devices…
The LUXE experiment is designed to explore the strong-field QED regime in interactions of high-energy electrons from the European XFEL in a powerful laser field. One of the crucial aims of this experiment is to measure the production of…
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…
It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally…
A gas cell for in-situ measurements of Volatile Organic Compounds (VOCs) and their adsorption behavior on different surfaces by means of X-Ray Fluorescence (XRF) and X-ray Absorption Fine-Structure (XAFS) spectroscopy has been developed.…
We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon…
In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…
The ALICE collaboration is preparing an upgrade of the three innermost layers of the current Inner Tracking System (ITS) during the next LHC long shutdown (LS3). The new ITS detector will use wafer-scale (up to \SI{27}{cm} in length)…
Sterile neutrinos are hypothetical particles in the minimal extension of the Standard Model of Particle Physics. They could be viable dark matter candidates if they have a mass in the keV range. The Karlsruhe tritium neutrino (KATRIN)…
X-rays spectroscopy experiments at synchrotron facilities were limited for many years by the maximum input-count rate and the signal-to-background ratio of germanium fluorescence detectors. These limitations are related to the germanium…
A monolithic silicon pixel ASIC prototype, produced in 2024 as part of the Horizon 2020 MONOLITH ERC Advanced project, was tested with a 120 GeV/c pion beam. The ASIC features a matrix of hexagonal pixels with a 100 \mu m pitch, read by…
The performace of an ATLAS-A silicon micro-strip detector prototype with FELIX 128 analogue read out chip has been studied. The noise level and the signal to noise ratio have been measured as a funtion of both detector bias and temperature.…