中文
相关论文

相关论文: Silicon photomultiplier-based Compton Telescope fo…

200 篇论文

Bioluminescence detection requires single-photon sensitivity, extremely low detection limits and wide dynamic range. Such performances were traditionally assured by photomultiplier-tubes based systems. However, development of novel…

仪器与探测器 · 物理学 2020-08-26 S. Lomazzi , M. Caccia , C. Distasi , M. Dionisi , D. Lim , A. Martemiyanov , L. Nardo , F. A. Ruffinatti , R. Santoro

This paper describes an experimental setup that has been developed to measure and characterise properties of Silicon Photomultipliers (SiPM). The measured SiPM properties are of general interest for a multitude of potential applications and…

仪器与探测器 · 物理学 2015-03-13 Patrick Eckert , Hans-Christian Schultz-Coulon , Wei Shen , Rainer Stamen , Alexander Tadday

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With…

天体物理学 · 物理学 2009-11-10 A. Takada , K. Hattori , H. Kubo , K. Miuchi , T. Nagayoshi , H. Nishimura , Y. Okada , R. Orito , H. Sekiya , A. Takeda , T. Tanimori

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The…

仪器与探测器 · 物理学 2018-10-17 X. L. Sun , T. Tolba , G. F. Cao , P. Lv , L. J. Wen , A. Odian , F. Vachon , A. Alamre , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , T. Bhatta , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , M. Côté , A. Craycraft , W. Cree , J. Dalmasson , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , R. DeVoe , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Feyzbakhsh , P. Fierlinger , R. Fontaine , D. Fudenberg , G. Gallina , G. Giacomini , R. Gornea , G. Gratta , E. V. Hansen , D. Harris , M. Heffner , E. W. Hoppe , J. Hößl , A. House , P. Hufschmidt , M. Hughes , Y. Ito , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , D. Kodroff , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , M. Moe , B. Mong , D. C. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , O. Nusair , K. Odgers , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retière , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , M. Tarka , J. Todd , T. I. Totev , R. Tsang , T. Tsang , B. Veenstra , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , Q. Wang , J. Watkins , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zhao , Y. Zhou , T. Ziegler

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

仪器与探测器 · 物理学 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to…

Due to their very fast signal rise time in the order of 1 ns, Silicon-Photomultipliers have become of increasing interest for many experiments that require very good timing resolution. With the prospect of an application in medical imaging…

仪器与探测器 · 物理学 2019-05-01 Reimund Bayerlein , Ivor Fleck , Todd Peterson , Albert H. Walenta

Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless {\beta}{\beta} decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of…

We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe…

Silicon photomultipliers (SiPMs) have a low radioactivity, compact geometry, low operation voltage, and reasonable photo-detection efficiency for vacuum ultraviolet light (VUV). Therefore it has the potential to replace photomultiplier…

仪器与探测器 · 物理学 2021-03-24 K. Ozaki , S. Kazama , M. Yamashita , Y. Itow , S. Moriyama

Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…

医学物理 · 物理学 2018-02-15 L. Caballero

The use of silicon photomultipliers (SiPMs) alongside conventional photomultiplier tubes (PMTs) is a remarkable technological development in modern ground-based very high energy gamma-ray astronomy. SiPMs exhibit comparable or even higher…

A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research…

仪器与探测器 · 物理学 2010-03-04 S. Korpar , I. Adachi , H. Chagani , R. Dolenec , K. Hara , T. Iijima , P. Krizan , S. Nishida , R. Pestotnik , A. Stanovnik

A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT…

天体物理学 · 物理学 2009-11-07 H. Tajima , T. Kamae , S. Uno , T. Nakamoto , Y. Fukazawa , T. Mitani , T. Takahashi , K. Nakazawa , Y. Oakada , M. Nomachi

The POSiCS camera is a handheld, small field-of-view gamma camera developed for multipurpose use in radio-guided surgery (RGS), with sentinel lymph node biopsy (SLNB) as its benchmark application. This compact and lightweight detector…

Among the main disadvantages of using silicon photomultipliers (SiPMs) in large experiments are their limited physical area (increasing the cost and the complexity of the readout of a camera) and their sensitivity to unwanted wavelengths.…

天体物理仪器与方法 · 物理学 2019-02-20 D. Guberman , J. Cortina , J. E. Ward , E. Do Souto Espiñera , A. Hahn , D. Mazin

Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…

仪器与探测器 · 物理学 2025-12-10 Veronika Asova , Galin Bistrev , Simeon Ivanov

Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An…

仪器与探测器 · 物理学 2014-07-01 V. Arosio , M. Caccia , V. Chmill , A. Ebolese , A. Martemiyanov , F. Risigo , R. Santoro , M. Locatelli , M. Pieracci , C. Tintori

Development of the Silicon photomultiplier Elementary Cell Add-on camera (SiECA) has provided extensive information regarding the use of SiPMs for future cosmic ray detection systems. We present the technical aspects of sensor readout…

天体物理仪器与方法 · 物理学 2019-08-27 W. Painter , A. Haungs , T. Huber , M. Karus , A. Menshikov , M. Oehler , M. Renschler , JEM-EUSO Collaboration

Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent…